Loss of the Pressure of the Blue Electric Pump
TASK 29-12-00-810-804-A
Loss of the Pressure of the Blue Electric Pump
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-12-00-810-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:22 UTC
Loss of the Pressure of the Blue Electric Pump
1. Possible Causes
- PACKAGE E-PUMP [2075GJ]
- HYD ACCU BLUE [2070GM]
- PRESS SW-ELEC PUMP, B [2074GJ]
- wiring
- CURRENT UNBAL.DETECT. [2707GJ]
- CURRENT UNBAL.DETECT. [3808GX]
- CURRENT TRANSFORMER [2706GJ]
- CURRENT TRANSFORMER [3807GX]
- C/B-B HYD/ELEC PUMP [2701GJ]
- CONTACTOR [2705GJ]
- RELAY-N2 SPEED CONDTN [2709GJ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-10-00-200-008 | Check Nitrogen Charge Pressure on Hydraulic Power Accumulators |
| AMM 29-12-00-710-001 | Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication |
| ASM 291201 | |
| AMM 29-12-15-000-001 | Removal of the Blue Electric-Pump Current Transformer |
| AMM 29-12-15-400-001 | Installation of the Blue Electric-Pump Current Transformer |
| AMM 29-12-17-000-001 | Removal of the Electric Pump Pressure-Switch |
| AMM 29-12-17-400-001 | Installation of the Electric Pump Pressure-Switch |
| AMM 29-12-18-000-001 | Removal of the Blue Electric Pump Phase-Unbalance Detector |
| AMM 29-12-18-400-001 | Installation of the Blue Electric Pump Phase-Unbalance Detector |
| AMM 29-12-42-000-001 | Removal of the Blue Power Accumulator |
| AMM 29-12-42-400-001 | Installation of the Blue Power Accumulator |
| AMM 29-12-51-000-001 | Removal of the Electric Pump |
| AMM 29-12-51-400-001 | Installation of the Electric Pump |
| AMM 29-12-55-000-001 | Removal of the Blue Electric-Pump Supply Contactor |
| AMM 29-12-55-400-001 | Installation of the Blue Electric-Pump Supply Contactor |
| AMM 29-24-51-000-001 | Removal of the Electric Pump |
| AMM 29-24-51-400-001 | Installation of the Electric Pump |
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 71-00-00-710-028 | Engine Shutdown |
NOTE: Continue with the step B. when the crew reported that the HYD B ELEC PUMP LO PRESS warning was shown for a short time during the start of the engines.
Subtask 29-12-00-710-052-A Subtask 29-12-00-710-070-A ** ON A/C NOT FOR ALL B. Do the subsequent test when the HYD B ELEC PUMP LO PRESS warning was shown for a short time during the start of the engines.
(1) Start the engine No. 2 AMM 71-00-00-710-003.
(2) Start the engine No. 1 AMM 71-00-00-710-003.
(3) Look at the upper ECAM DU for the warning HYD B ELEC PUMP LO PRESS.
(4) Shutdown the engines AMM 71-00-00-710-028.
Subtask 29-12-00-710-070-B ** ON A/C NOT FOR ALL (1) Start the engine No. 2 AMM 71-00-00-710-003.
(2) Start the engine No. 1 AMM 71-00-00-710-003.
(3) Look at the upper ECAM DU for the warning HYD B ELEC PUMP LO PRESS.
(4) Shutdown the engines AMM 71-00-00-710-028.
B. Do the subsequent test when the HYD B ELEC PUMP LO PRESS warning was shown for a short time during the start of the engines.
(1) Start the engine No. 2 AMM 71-00-00-710-003.
(2) Start the engine No. 1 AMM 71-00-00-710-003.
(3) Look at the upper ECAM DU for the warning HYD B ELEC PUMP LO PRESS.
(4) Shutdown the engines AMM 71-00-00-710-028.
4. Fault Isolation(1) Start the engine No. 2 AMM 71-00-00-710-003.
(2) Start the engine No. 1 AMM 71-00-00-710-003.
(3) Look at the upper ECAM DU for the warning HYD B ELEC PUMP LO PRESS.
(4) Shutdown the engines AMM 71-00-00-710-028.
Subtask 29-12-00-810-052-A
A. If the test gives:
1 Do a check of the nitrogen charge pressure of the Blue hydraulic power accumulator AMM 29-10-00-200-008.
a If necessary, replace the HYD ACCU BLUE [2070GM] AMM 29-12-42-000-001 and AMM 29-12-42-400-001.
2 If the fault continues:
a Replace the PACKAGE E-PUMP [2075GJ] AMM 29-12-51-000-001 and AMM 29-12-51-400-001.
Subtask 29-12-00-810-073-A - HYD B ELEC PUMP LO PR on the upper ECAM DU,
- LO flag of the BLUE hydraulic system on the HYD page of the lower ECAM DU,
- BLUE ELEC PUMP P/BSW FAULT on panel 40VU,
do the steps that follows: - examine if the Blue electric pump operates.
- look on the ECAM SD - DU and do a check of the pressure indication.
1 Do a check of the nitrogen charge pressure of the Blue hydraulic power accumulator AMM 29-10-00-200-008.
a If necessary, replace the HYD ACCU BLUE [2070GM] AMM 29-12-42-000-001 and AMM 29-12-42-400-001.
2 If the fault continues:
a Replace the PACKAGE E-PUMP [2075GJ] AMM 29-12-51-000-001 and AMM 29-12-51-400-001.
NOTE: You can replace the ELEC PUMP-B (2075GJ) with the ELEC PUMP-Y (3075GX) which is interchangeable, if a new pump is not available AMM 29-24-51-000-001 and AMM 29-24-51-400-001.
(b) If the pressure is more than 1450 psi (99.9740 bar): - do a check for continuity between:
PRESS SW-ELEC PUMP, B [2074GJ] connector A/A and connector A/C - repair the wiring as necessary ASM 291201.
- replace the PRESS SW-ELEC PUMP, B [2074GJ] AMM 29-12-17-000-001 and AMM 29-12-17-400-001.
- do a check of the wiring for a GND connection between:
PRESS SW-ELEC PUMP, B [2074GJ] connector A/C and the SDAC connector AA/04F ASM 291201.
- repair the wiring as necessary.
- do a check of the red indicator light on the CURRENT UNBAL.DETECT. [2707GJ] .
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
(a) If the red indicator light is on: - put the BLUE ELEC PUMP P/BSW (2704GJ) on panel 40VU in the OFF position ( OFF light is on and the red indicator light on the CURRENT UNBAL.DETECT. [2707GJ] goes off),
- put the BLUE ELEC PUMP P/BSW (2704GJ) in the AUTO position (OFF light goes off),
- put the BLUE PUMP OVRD P/BSW (2703GJ) on panel 50VU in the ON position
- look on the SD - DU and examine if the PACKAGE E-PUMP [2075GJ] operates.
- no more actions are necessary.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
2 If the PACKAGE E-PUMP [2075GJ] does not operate and the red indicator light CURRENT UNBAL.DETECT. [2707GJ] comes on again: - interchange the CURRENT UNBAL.DETECT. [2707GJ] and CURRENT UNBAL.DETECT. [3808GX] AMM 29-12-18-000-001 and AMM 29-12-18-400-001
- interchange the CURRENT TRANSFORMER [2706GJ] and CURRENT TRANSFORMER [3807GX] AMM 29-12-15-000-001 and AMM 29-12-15-400-001
- put the BLUE ELEC PUMP P/BSW (2704GJ) on panel 40VU in the OFF position ( OFF light is on and the red indicator light on the CURRENT UNBAL.DETECT. [2707GJ] goes off)
- put the BLUE ELEC PUMP P/BSW (2704GJ) in the AUTO position (OFF light goes off)
- put the BLUE PUMP OVRD P/BSW (2703GJ) on panel 50VU in the ON position
- look on the SD - DU and examine if the PACKAGE E-PUMP [2075GJ] operates.
- replace the PACKAGE E-PUMP [2075GJ] AMM 29-24-51-000-001 and AMM 29-24-51-400-001.
NOTE: You can replace the ELEC PUMP-B (2075GJ) with the ELEC PUMP-Y (3075GX) which is interchangeable, if a new pump is not available AMM 29-24-51-000-001 and AMM 29-24-51-400-001.
4 If the PACKAGE E-PUMP [2075GJ] operates at normal pressure and the red indicator light on the CURRENT UNBAL.DETECT. [2707GJ] does not come on: - interchange the CURRENT UNBAL.DETECT. [2707GJ] and CURRENT UNBAL.DETECT. [3808GX] AMM 29-12-18-000-001 and AMM 29-12-18-400-001
- interchange the CURRENT TRANSFORMER [2706GJ] and CURRENT TRANSFORMER [3807GX] AMM 29-12-15-000-001 and AMM 29-12-15-400-001
- continue the procedure as if the red indicator light is not on.
- do a check for 115VAC between:
the PACKAGE E-PUMP [2075GJ] connectors A/G and A/A, A/B, A/C.
- replace the PACKAGE E-PUMP [2075GJ] AMM 29-12-51-000-001 and AMM 29-12-51-400-001.
NOTE: You can replace the ELEC PUMP-B (2075GJ) with the ELEC PUMP-Y (3075GX) which is interchangeable, if a new pump is not available AMM 29-24-51-000-001 and AMM 29-24-51-400-001.
2 If there are no 115VAC: - do a check for 115VAC between the ground and each pin of the C/B-B HYD/ELEC PUMP [2701GJ] .
- replace the C/B-B HYD/ELEC PUMP [2701GJ] .
- do a check for 28VDC between the CURRENT UNBAL.DETECT. [2707GJ] connectors A/G and A/F.
- replace the CURRENT TRANSFORMER [2706GJ] AMM 29-12-15-000-001 and AMM 29-12-15-400-001.
- replace the CURRENT UNBAL.DETECT. [2707GJ] AMM 29-12-18-000-001 and AMM 29-12-18-400-001.
- replace the CONTACTOR [2705GJ] AMM 29-12-55-000-001 and AMM 29-12-55-400-001.
- do a check of the wiring between: CURRENT UNBAL.DETECT. [2707GJ] connector A/D and CONTACTOR [2705GJ] B/3
- repair as necessary.
- do a check of the wiring between:
PACKAGE E-PUMP [2075GJ] connectors A/A, A/B and A/C and CB (2701GJ) - repair as necessary.
- do a check of the wiring between: CURRENT UNBAL.DETECT. [2707GJ] connector A/F and CB (2702GJ)
- repair as necessary.
B. If the HYD B ELEC PUMP LO PRESS warning was shown for a short time during the fault confirmation with engines running:
Subtask 29-12-00-710-055-A - Replace the RELAY-N2 SPEED CONDTN [2709GJ] .
C. Do the test as given in Para. 3. A. or 3. B. to make sure that operation is correct.