Symbol of the ENG 1 Pump on the ECAM Lower DU shows the incorrect Position (when the G HYD SYS is Pressurized with the Ground Cart or the PTU)
TASK 29-11-00-810-819-A
Symbol of the ENG 1 Pump on the ECAM Lower DU shows the incorrect Position (when the G HYD SYS is Pressurized with the Ground Cart or the PTU)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-11-00-710-069-A ** ON A/C NOT FOR ALL
Subtask 29-11-00-810-075-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:21 UTC
Symbol of the ENG 1 Pump on the ECAM Lower DU shows the incorrect Position (when the G HYD SYS is Pressurized with the Ground Cart or the PTU)
1. Possible Causes
- MANIFOLD PYLON [1030GM]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-10-00-863-001 | Pressurize the Green Hydraulic System with a Hydraulic Ground Power-Cart |
| AMM 29-11-16-000-801 | Removal of the Pylon Manifold |
| AMM 29-11-16-400-801 | Installation of the Pylon Manifold |
| AMM 29-24-00-863-001 | Pressurize the Yellow Hydraulic System with the Electric Pump |
Subtask 29-11-00-710-069-A ** ON A/C NOT FOR ALL
A. Pressurize the Green hydraulic system
AMM 29-10-00-863-001 or AMM 29-24-00-863-001
(1) If during the test, the ENG 1 pump symbol on the HYD page of the lower ECAM DU shows in-line in green color:
(a) Stop the pressurization of the hydraulic system immediately.
(b) Do the fault isolation procedure given in paragraph 4.
4. Fault IsolationAMM 29-10-00-863-001 or AMM 29-24-00-863-001
(1) If during the test, the ENG 1 pump symbol on the HYD page of the lower ECAM DU shows in-line in green color:
(a) Stop the pressurization of the hydraulic system immediately.
(b) Do the fault isolation procedure given in paragraph 4.
Subtask 29-11-00-810-075-A ** ON A/C NOT FOR ALL
A. If during the test the ENG 1 pump symbol on the HYD page of the lower ECAM DU shows:
(2) Do the test given in paragraph 3.
- In-line in green color and the system pressure is correct:
(2) Do the test given in paragraph 3.