Green Reservoir Pressure is out of Tolerance
TASK 29-11-00-810-810-A
Green Reservoir Pressure is out of Tolerance
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 29-11-00-865-055-A
Subtask 29-11-00-810-061-A
Subtask 29-11-00-865-056-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:20 UTC
Green Reservoir Pressure is out of Tolerance
1. Possible Causes
- PRESSURE REDUCING VALVE
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-32-29-281-001 | Hydraulic Fluid Sample of Green, Blue and Yellow Systems for Analysis |
| AMM 29-00-00-864-001 | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| AMM 29-14-00-720-001 | Functional Test of the Pressurizing System of the Hydraulic Reservoirs |
| AMM 29-14-43-000-001 | Removal of the Pressure Reducing Valve |
| AMM 29-14-43-400-001 | Installation of the Pressure Reducing Valve |
| AMM 32-12-00-010-001 | Open the Main Gear Doors for Access |
Subtask 29-11-00-865-055-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-11-00-860-058-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
B. Aircraft Maintenance Configuration
(1) Depressurize the Green, Yellow and Blue hydraulic systems, but not the reservoirs AMM 29-00-00-864-001.
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems:
(4) Open the right main door of the main landing gear AMM 32-12-00-010-001.
(5) Read the pressure gages (1383GM, 2383GM, 3383GM) on each hydraulic reservoir.
(6) If the reservoir pressure indication is more than 52 +2 psi or -2 psi (3.5853 +0.1379 bar or -0.1379 bar):
(a) Do the functional test of the pressurizing system of the hydraulic reservoirs AMM 29-14-00-720-001.
4. Fault Isolation(1) Depressurize the Green, Yellow and Blue hydraulic systems, but not the reservoirs AMM 29-00-00-864-001.
(2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems:
- in the flight compartment on the hydraulic section 40VU of the overhead panel,
- on the ground service panels of the Green, Yellow and Blue hydraulic systems.
(4) Open the right main door of the main landing gear AMM 32-12-00-010-001.
(5) Read the pressure gages (1383GM, 2383GM, 3383GM) on each hydraulic reservoir.
(6) If the reservoir pressure indication is more than 52 +2 psi or -2 psi (3.5853 +0.1379 bar or -0.1379 bar):
(a) Do the functional test of the pressurizing system of the hydraulic reservoirs AMM 29-14-00-720-001.
Subtask 29-11-00-810-061-A
A. If the reservoir pressure increases during the test to more than 50 +2 psi or -2 psi (3.4474 +0.1379 bar or -0.1379 bar):
(1) Replace the PRESSURE REDUCING VALVE AMM 29-14-43-000-001 and AMM 29-14-43-400-001.
(2) Take a fluid sample from each hydraulic system to make sure that the contamination of the hydraulic fluid is in the approved values AMM 12-32-29-281-001.
Subtask 29-11-00-720-050-A (1) Replace the PRESSURE REDUCING VALVE AMM 29-14-43-000-001 and AMM 29-14-43-400-001.
(2) Take a fluid sample from each hydraulic system to make sure that the contamination of the hydraulic fluid is in the approved values AMM 12-32-29-281-001.
B. Do the functional test of the pressurizing system of the hydraulic reservoirs again to make sure that the function is correct AMM 29-14-00-720-001.
5. Close-upSubtask 29-11-00-865-056-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |