Overheat Indication of the Green Hydraulic System
TASK 29-11-00-810-802-A
Overheat Indication of the Green Hydraulic System
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 29-11-00-865-052-A
Subtask 29-11-00-810-051-A ** ON A/C NOT FOR ALL
Subtask 29-11-00-860-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:19 UTC
Overheat Indication of the Green Hydraulic System
1. Possible Causes
- internal leakage
- RELIEF VALVE G SYS [1063GM]
- LP FILTER [1002GM]
- HP FILTER G [1048GM]
[1059GM] - CHECK VALVE G [1022GM]
- FILTER-ENG PUMP CASE DRAIN [1084GM]
TEMP TRANSM SWITCH-connector plug (1381GR-A) - TEMP TRANSM SWITCH [1381GR]
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
RELAY-G RSVR OVHT FAULT (1708GK) - SAFETY VALVE-L/G SYS ISOLATION [49GA]
[40GA] [41GA] - PTU [1088GM]
- FIRE-S.-O.V. [1046GK]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | OHMMETER MODEL 260 |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 29-00-00-280-001 | Check of the Internal Leakage of the Green Hydraulic System |
| AMM 29-00-00-280-004 | Check of the Internal Leakage of the Power Transfer Unit (PTU) |
| AMM 29-00-00-280-006 | Check of the Green or Yellow Hydraulic System after Engine Pump Failure or Operation in a Possible Cavitation Condition - with Ground Cart Available |
| AMM 29-00-00-910-003 | General Removal and Installation Procedure of the Check Valves in the Hydraulic Systems |
| AMM 29-10-00-710-001 | Operational Check of Hydraulic Fire Shut Off Valves and Associated Indicating System |
| ASM 291101 | |
| AMM 29-11-32-000-001 | Removal of the Pressure Relief Valve of the Green Hydraulic System |
| AMM 29-11-32-400-001 | Installation of the Pressure Relief Valve of the Green Hydraulic System |
| AMM 29-11-43-610-040 | Servicing of the Engine-Pump Case-Drain Filter |
| AMM 29-11-44-610-001 | Servicing of the LP-Filter |
| AMM 29-11-45-610-001 | Servicing of the HP-Filter |
| ASM 293301 | |
| AMM 29-33-11-000-001 | Removal of the Temperature Transmitter |
| AMM 29-33-11-400-001 | Installation of the Temperature Transmitter |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 71-00-00-710-028 | Engine Shutdown |
Subtask 29-11-00-865-052-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-11-00-710-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
B. Test
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) Do an Engine Automatic Start to pressurize the Green hydraulic system AMM 71-00-00-710-003.
(4) Operate the sidestick for ailerons, spoilers and elevators at full travel for 5 min.
(5) Operate the rudder pedals at full travel for 5 min.
(6) Operate the flap and slat control lever at full travel for 5 min.
4. Fault IsolationWARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
(1) Energize the aircraft electrical circuitsAMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) Do an Engine Automatic Start to pressurize the Green hydraulic system AMM 71-00-00-710-003.
(4) Operate the sidestick for ailerons, spoilers and elevators at full travel for 5 min.
(5) Operate the rudder pedals at full travel for 5 min.
(6) Operate the flap and slat control lever at full travel for 5 min.
Subtask 29-11-00-810-051-A ** ON A/C NOT FOR ALL
A. If the test gives:
(a) If the internal leakage is more than permitted:
(b) If the internal leakage is in the given limits:
1 Do a check of the filter elements of the FILTER-ENG PUMP CASE DRAIN [1084GM] , HP FILTER G [1048GM] and LP FILTER [1002GM] .
2 Replace the filter element as necessary AMM 29-11-43-610-040 or AMM 29-11-45-610-001 or AMM 29-11-44-610-001.
Subtask 29-11-00-810-051-C ** ON A/C NOT FOR ALL - The message HYD G RSVR OVHT on the upper ECAM DU
- The PTU P/BSW FAULT light on panel 40VU
- The GREEN ENG 1 PUMP P/BSW FAULT light on panel 40VU
- The OVHT flag on the HYD page of the lower ECAM DU.
NOTE: The fault warning system shows, that the temperature is more than 95 +2.2 deg.C or -2.2 deg.C (203.00 +3.96 deg.F or -3.96 deg.F). This was detected by the temperature (TEMP) transducers (XDCRs) and the thermal switch of the reservoir (RSVR) TEMP sensor FIN 1381GR.
(1) Do a check of the internal leakage of the Green hydraulic system AMM 29-00-00-280-001 and the PTU AMM 29-00-00-280-004. (a) If the internal leakage is more than permitted:
- Examine the system to find the defective component
- Replace or repair the defective component.
- RELIEF VALVE G SYS [1063GM] AMM 29-11-32-000-001 AMM 29-11-32-400-001
- LP FILTER [1002GM] AMM 29-11-44-610-001
- HP FILTER G [1048GM] AMM 29-11-45-610-001
- if installed,
[1059GM] AMM 29-00-00-910-003 - CHECK VALVE G [1022GM] AMM 29-00-00-910-003.
(b) If the internal leakage is in the given limits:
1 Do a check of the filter elements of the FILTER-ENG PUMP CASE DRAIN [1084GM] , HP FILTER G [1048GM] and LP FILTER [1002GM] .
2 Replace the filter element as necessary AMM 29-11-43-610-040 or AMM 29-11-45-610-001 or AMM 29-11-44-610-001.
A. If the test gives:
(a) If the internal leakage is more than permitted:
(b) If the internal leakage is in the given limits:
1 Do a check of the filter elements of the FILTER-ENG PUMP CASE DRAIN [1084GM] , HP FILTER G [1048GM] and LP FILTER [1002GM] .
2 Replace the filter element as necessary AMM 29-11-43-610-040 or AMM 29-11-45-610-001 or AMM 29-11-44-610-001.
Subtask 29-11-00-810-070-A - The message HYD G RSVR OVHT on the upper ECAM DU
- The PTU P/BSW FAULT light on panel 40VU
- The GREEN ENG 1 PUMP P/BSW FAULT light on panel 40VU
- The OVHT flag on the HYD page of the lower ECAM DU.
NOTE: The fault warning system shows, that the temperature is more than 100 +2.2 deg.C or -2.2 deg.C (212.00 +3.96 deg.F or -3.96 deg.F). This was detected by the temperature (TEMP) transducers (XDCRs) and the thermal switch of the reservoir (RSVR) TEMP sensor FIN 1381GR.
(1) Do a check of the internal leakage of the Green hydraulic system AMM 29-00-00-280-001 and the PTU AMM 29-00-00-280-004. (a) If the internal leakage is more than permitted:
- Examine the system to find the defective component
- Replace or repair the defective component.
- RELIEF VALVE G SYS [1063GM] AMM 29-11-32-000-001 AMM 29-11-32-400-001
- LP FILTER [1002GM] AMM 29-11-44-610-001
- HP FILTER G [1048GM] AMM 29-11-45-610-001
- if installed,
[1059GM] AMM 29-00-00-910-003 - CHECK VALVE G [1022GM] AMM 29-00-00-910-003.
(b) If the internal leakage is in the given limits:
1 Do a check of the filter elements of the FILTER-ENG PUMP CASE DRAIN [1084GM] , HP FILTER G [1048GM] and LP FILTER [1002GM] .
2 Replace the filter element as necessary AMM 29-11-43-610-040 or AMM 29-11-45-610-001 or AMM 29-11-44-610-001.
B. If the test gives:
(a) Disconnect theTEMP TRANSM SWITCH-connector plug (1381GR-A) from the TEMP TRANSM SWITCH [1381GR] and do a visual check of the connector's integrity.
1 If the connector is not in the correct condition:
1 If there is no continuity, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
(c) Do a check of the continuity between pin A/F and pin A/E of the TEMP TRANSM SWITCH [1381GR] ASM 293301.
1 If there is no continuity, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
(d) Measure the DC resistance between the pins A/G and A/K and between the pins A/E and A/F of the TEMP TRANSM SWITCH [1381GR] with an OHMMETER MODEL 260.
1 If the difference is more than 1.5 Ohm between the two measurements, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
(e) If the fault continues, make sure that the wiring is not connected to GND between theTEMP TRANSM SWITCH-connector plug (1381GR-A) , pin E and the SDAC-1 [1WV1] connector AB, pin 12A ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(f) If the fault continues, make sure that the wiring is not connected to GND between theTEMP TRANSM SWITCH-connector plug (1381GR-A) , pin K and the SDAC-2 [1WV2] connector AB, pin 12A ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(g) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC1 : G HYD TEMP XMTR 1381GR:
Subtask 29-11-00-810-071-A - The message HYD G RSVR OVHT on the upper ECAM DU
- The OVHT flag on the HYD page of the lower ECAM DU.
NOTE: If the P/BSW FAULT lights are not on, the OVHT warning condition is only detected by the TEMP XDCRs of the RSVR TEMP sensor FIN 1381GR. It is referred to as a spurious warning from the TEMP XDCRs or wiring or System Data Acquisition Concentrators (SDACs).
(1) Do a wiring check: (a) Disconnect the
1 If the connector is not in the correct condition:
- Replace the TEMP TRANSM SWITCH [1381GR] , AMM 29-33-11-000-001 AMM 29-33-11-400-001 and replace the
TEMP TRANSM SWITCH-connector plug (1381GR-A) .
1 If there is no continuity, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
(c) Do a check of the continuity between pin A/F and pin A/E of the TEMP TRANSM SWITCH [1381GR] ASM 293301.
1 If there is no continuity, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
(d) Measure the DC resistance between the pins A/G and A/K and between the pins A/E and A/F of the TEMP TRANSM SWITCH [1381GR] with an OHMMETER MODEL 260.
1 If the difference is more than 1.5 Ohm between the two measurements, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
(e) If the fault continues, make sure that the wiring is not connected to GND between the
1 If the wiring is connected to GND, repair the wiring as necessary.
(f) If the fault continues, make sure that the wiring is not connected to GND between the
1 If the wiring is connected to GND, repair the wiring as necessary.
(g) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC1 : G HYD TEMP XMTR 1381GR:
- Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- Replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
C. If the test gives:
(a) Do a check of the continuity between pin A/A and pin A/B of the TEMP TRANSM SWITCH [1381GR] ASM 293301.
1 If there is continuity, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
2 If there is no continuity, make sure that the wiring is not connected to GND between theTEMP TRANSM SWITCH-connector plug (1381GR-A) , pin B and the RELAY-G RSVR OVHT FAULT (1708GK) , pin Z ASM 293301 ASM 291101.
a If the wiring is connected to GND, repair the wiring as necessary.
(b) If the fault continues, make sure that the wiring is not connected to GND between theTEMP TRANSM SWITCH-connector plug (1381GR-A) , pin B and the SDAC-1 [1WV1] connector AA, pin 4A ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(c) If the fault continues, make sure that the wiring is not connected to GND between theTEMP TRANSM SWITCH-connector plug (1381GR-A) , pin B and the SDAC-2 [1WV2] connector AA, pin 4A ASM 293301.
1 If the wiring is connected to GND, repair the wiring as necessary.
(d) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC1 : G HYD TEMP XMTR 1381GR:
Subtask 29-11-00-810-063-A - The message HYD G RSVR OVHT on the upper ECAM DU
- The PTU P/BSW FAULT light on panel 40VU
- The GREEN ENG 1 PUMP P/BSW FAULT light on panel 40VU.
NOTE: If the OVHT flag is not shown on the HYD page of the lower ECAM DU, the OVHT warning condition is only detected by the thermal switch of the RSVR TEMP sensor FIN 1381GR. It is referred to as a spurious warning from the thermal switch or wiring or SDACs.
(1) Do a wiring check: (a) Do a check of the continuity between pin A/A and pin A/B of the TEMP TRANSM SWITCH [1381GR] ASM 293301.
1 If there is continuity, replace the TEMP TRANSM SWITCH [1381GR] AMM 29-33-11-000-001 AMM 29-33-11-400-001.
2 If there is no continuity, make sure that the wiring is not connected to GND between the
a If the wiring is connected to GND, repair the wiring as necessary.
(b) If the fault continues, make sure that the wiring is not connected to GND between the
1 If the wiring is connected to GND, repair the wiring as necessary.
(c) If the fault continues, make sure that the wiring is not connected to GND between the
1 If the wiring is connected to GND, repair the wiring as necessary.
(d) If the fault continues, do the operational test of the central warning system AMM 31-50-00-710-001.
1 If the test gives the maintenance message SDAC1 : G HYD TEMP XMTR 1381GR:
- Replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- Replace the SDAC-2 [1WV2] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
D. If the test gives:
(1) Do a check of the internal leakage of the Green hydraulic system AMM 29-00-00-280-001.
(a) If the internal leakage is more than permitted:
(4) Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
Subtask 29-11-00-710-056-A - No messages on the upper and lower ECAM DU
- No FAULT lights on the panel 40VU.
(1) Do a check of the internal leakage of the Green hydraulic system AMM 29-00-00-280-001.
(a) If the internal leakage is more than permitted:
- Examine the system to find the defective component
- Replace or repair the defective component.
- Do a check for local increase of the temperature and unusual noise of SAFETY VALVE-L/G SYS ISOLATION [49GA] ,
[40GA] and [41GA] . - Do a test for internal leakage of the PTU [1088GM] AMM 29-00-00-280-004.
NOTE: If the VALVE-G PUMP FIRE, ENG 1 FIRE-S.-O.V. [1046GK] is not in the fully open position, this can be the cause of an overheat of the hydraulic system.
(3) If the operational test gives an unsatisfactory operation of the VALVE-G PUMP FIRE, ENG 1 FIRE-S.-O.V. [1046GK] , replace the VALVE-G PUMP FIRE, ENG 1 FIRE-S.-O.V. [1046GK] : (4) Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
NOTE: A cavitation condition of the engine pump is possible when the engine pump operates with the engine pump fire valve closed (if you set the ENG 1 (2) FIRE pushbutton on the Eng/APU fire panel), or with the reservoir below the low level (ECAM indication).
E. When the FIRE-S.-O.V. [1046GK] was not the cause of the malfunction:
5. Close-up- Do the test as given in Para. 3. B. to make sure that operation is correct (no message shown).
Subtask 29-11-00-860-052-A
A. Aircraft Maintenance Configuration
(1) Stop the Engine AMM 71-00-00-710-028.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) Stop the Engine AMM 71-00-00-710-028.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.