External Leakage found on Components of the Hydraulic System


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-00-00-280-006
Check of the Green or Yellow Hydraulic System after Engine Pump Failure or Operation in a Possible Cavitation Condition - with Ground Cart Available
AMM 29-00-00-790-001
Check of the External Leaks of the Hydraulic Components
3. Fault Confirmation
Subtask 29-10-00-869-050-A
A. Do a check of external leakage of the related component AMM 29-00-00-790-001.
NOTE: Do the check of the Green or Yellow hydraulic system after operation in a possible cavitation condition of the engine pump if the hydraulic engine pump of the related hydraulic system has operated for more than 5 minutes:
  • with closed engine pump fire valves and/or
  • with the RSVR LO LVL warning on the upper ECAM DU
    AMM 29-00-00-280-006.
4. Fault Isolation
Subtask 29-10-00-810-053-A
A. If the fault confirmation gives that the leakage is out of tolerance:
  • repair or replace the component as necessary.
Subtask 29-10-00-869-051-A
B. Do the check as given in Para. 3. A. to make sure that no leakage occurs.