ACT 1 - FLSCU-3 Channel LS1 - Low Level Sensor No. 1 Failure
TASK 28-46-00-810-828-A
ACT 1 - FLSCU-3 Channel LS1 - Low Level Sensor No. 1 Failure
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 28-46-00-865-076-A ** ON A/C NOT FOR ALL
Subtask 28-46-00-810-077-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:39:44 UTC
ACT 1 - FLSCU-3 Channel LS1 - Low Level Sensor No. 1 Failure
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causes2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-11-28-650-003 | Pressure Refuel with Automatic Control |
| AMM 28-25-00-869-001 | Fuel Transfer |
| ASM 282803 | |
| AMM 28-42-24-000-001 | Removal of the Fuel Quantity Probe of the ACT |
| AMM 28-42-24-400-001 | Installation of the Fuel Quantity Probe of the ACT |
| ASM 284602 | |
| AMM 28-46-34-000-001 | Removal of the Fuel-Level Sensing Control-Unit (FLSCU) |
| AMM 28-46-34-400-001 | Installation of the Fuel-Level Sensing Control-Unit (FLSCU) |
Subtask 28-46-00-865-076-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers referred to in this procedure:
Subtask 28-46-00-710-059-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT LOW LVL L | 52QJ | M28 |
B. Test
FLSCU-3 (47QJ), CHAN LS1 - LO LVL SENSOR No. 1 (65QT1) Input To RELAY-PANEL (802VU) Fault Confirmation
(3) Use a MULTIMETER - STANDARD, to do a test for continuity, at the free connector 4065VC-A, between the pin <D and an applicable ground. This test must show an open circuit. If the test shows continuity, do the fault isolation procedure in Para. 4.A.
(4) Defuel the ACT 1 AMM 28-25-00-869-001.
(6) If the test results are:
(a) As specified in steps (3) thru (5):
1 No more Trouble-shooting steps of the FLSCU-3 (47QJ) Channel LS1 - Low Level Sensor No. 1 (65QT1) are necessary.
2 Connect the free connector 4065VC-A to the RELAY-PANEL (802VU).
(b) Not as specified in steps (3) thru (5):
4. Fault IsolationFLSCU-3 (47QJ), CHAN LS1 - LO LVL SENSOR No. 1 (65QT1) Input To RELAY-PANEL (802VU) Fault Confirmation
NOTE: The ACT Low Level sensors are not FQIC BITE tested, manually tested or monitored by the FQIC during normal operation.
NOTE: OPTIONAL TESTING:
If a PSDA321-1 Test Set is available, a check can be made before a decision is made to go into or close up a fuel tank. The Test Set lets a GO/NOGO check be made of the tank mounted components and wiring from the tank wall connectors.
(1) Examine the FUEL System Display ACT 1 FQ, and make sure it contains more than 250 kg (560 lb): If a PSDA321-1 Test Set is available, a check can be made before a decision is made to go into or close up a fuel tank. The Test Set lets a GO/NOGO check be made of the tank mounted components and wiring from the tank wall connectors.
- refuel the ACT 1 AMM 12-11-28-650-003 if necessary.
NOTE: This is to make sure the low level sensor is wet.
The fuel quantity/level at which the low level sensor changes state/operates is approximately 80 kg (180 lb) with the aircraft in a level attitude.
(2) Disconnect the free connector 4065VC-A from the RELAY-PANEL (802VU). The fuel quantity/level at which the low level sensor changes state/operates is approximately 80 kg (180 lb) with the aircraft in a level attitude.
(3) Use a MULTIMETER - STANDARD, to do a test for continuity, at the free connector 4065VC-A, between the pin <D and an applicable ground. This test must show an open circuit. If the test shows continuity, do the fault isolation procedure in Para. 4.A.
(4) Defuel the ACT 1 AMM 28-25-00-869-001.
NOTE: This is to make sure the low level sensor is dry.
(5) Use a multimeter, to do a test for continuity, at the free connector 4065VC-A, between the pin <D and an applicable ground. This test must show continuity. (6) If the test results are:
(a) As specified in steps (3) thru (5):
1 No more Trouble-shooting steps of the FLSCU-3 (47QJ) Channel LS1 - Low Level Sensor No. 1 (65QT1) are necessary.
2 Connect the free connector 4065VC-A to the RELAY-PANEL (802VU).
(b) Not as specified in steps (3) thru (5):
- go to Para. 4. and do the fault isolation.
Subtask 28-46-00-810-077-A ** ON A/C NOT FOR ALL
A. Procedure
(1) Examine the C/B-ACT PROBE LO LVL LEFT (52QJ) and make a note if it is open or closed.
(2) If the C/B 52QJ is closed:
(a) Do a visual check of the items that follow and repair if necessary:
1 C/B 52QJ.
2 FLSCU-3 (47QJ).
3 FLSCU-3 rack connector (47QJ-A).
(b) Close the C/B 52QJ.
(c) Do the test given in Para. 3.B.
(4) Interchange the FLSCU-3 (47QJ) with FLSCU-1 (7QJ) AMM 28-46-34-000-001 and AMM 28-46-34-400-001.
(5) Do the test given in Para. 3.B.
(a) If the test is satisfactory:
1 Install the original FLSCU-1 in the FLSCU-1 position.
2 Replace the FLSCU 3 [47QJ] AMM 28-46-34-000-001 and AMM 28-46-34-400-001.
(b) If the fault continues:
(10) Do the test given in Para. 3.B.
(11) If the fault continues:
(13) If the 28VDC is available:
(a) Install the FLSCU-3 (47QJ) AMM 28-46-34-400-001.
(b) Go to Step (15).
(14) If the 28VDC is not available:
(a) Do a check of and replace if necessary the C/B-ACT LOW LVL L [52QJ] .
(b) Do a check of the aircraft wiring ASM 284602:
(d) Install the FLSCU-3 (47QJ) AMM 28-46-34-400-001.
(e) Do the test given in Para. 3.B.
(15) If the fault continues:
(1) Examine the C/B-ACT PROBE LO LVL LEFT (52QJ) and make a note if it is open or closed.
(2) If the C/B 52QJ is closed:
- go to Step (4).
(a) Do a visual check of the items that follow and repair if necessary:
1 C/B 52QJ.
2 FLSCU-3 (47QJ).
3 FLSCU-3 rack connector (47QJ-A).
(b) Close the C/B 52QJ.
(c) Do the test given in Para. 3.B.
(4) Interchange the FLSCU-3 (47QJ) with FLSCU-1 (7QJ) AMM 28-46-34-000-001 and AMM 28-46-34-400-001.
(5) Do the test given in Para. 3.B.
(a) If the test is satisfactory:
1 Install the original FLSCU-1 in the FLSCU-1 position.
2 Replace the FLSCU 3 [47QJ] AMM 28-46-34-000-001 and AMM 28-46-34-400-001.
(b) If the fault continues:
- install the FLSCUs in their original positions AMM 28-46-34-000-001 and AMM 28-46-34-400-001.
WARNING:
WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
(a) If there is: - approved test equipment available, go to Step (7)
- no approved test equipment available, go to Step (8).
NOTE: The sensor status (wet or dry) and fuel/air temperature will have an effect on the resistance value.
(a) If the resistance is between 330 and 480 ohms: - go to Step (8).
- go to Step (15).
- the FLSCU-3 rack connector AB, pin 15A and the ACT to tank break connector 7617VC1, pin 9 (sensor input line - H)
- the FLSCU-3 rack connector AB, pin 15B and the ACT to tank break connector 7617VC1, pin 10 (sensor input line - L)
- the ACT aircraft to tank break free connector 7617VC1-A, pin 9 and the tank unit free connector 65QT1-A, pin E (sensor input line - H)
- the ACT aircraft to tank break free connector 7617VC1-A, pin 10 and the tank unit free connector 65QT1-A, pin D (sensor input line - L)
- the FLSCU-3 rack connector AA, pin 3A and the ground/earth point DC1 (ground/earth I/P)
- the FLSCU-3 rack connector AA, pin 4A and the RELAY-PANEL (802VU) free connector 4065VC, pin <D (LS1 channel output line to RELAY-PNL 802VU).
(10) Do the test given in Para. 3.B.
(11) If the fault continues:
- remove the FLSCU-3 (47QJ) AMM 28-46-34-000-001.
(13) If the 28VDC is available:
(a) Install the FLSCU-3 (47QJ) AMM 28-46-34-400-001.
(b) Go to Step (15).
(14) If the 28VDC is not available:
(a) Do a check of and replace if necessary the C/B-ACT LOW LVL L [52QJ] .
(b) Do a check of the aircraft wiring ASM 284602:
- between the C/B-ACT PROBE LO LVL LEFT (52QJ) terminal 2 and the FLSCU-3 rack connector AA, pin 1A (28VDC supply line).
(d) Install the FLSCU-3 (47QJ) AMM 28-46-34-400-001.
(e) Do the test given in Para. 3.B.
(15) If the fault continues:
- replace the PROBE-FQI NO 1, ACT1 [65QT1] AMM 28-42-24-000-001 and AMM 28-42-24-400-001.