RIGHT HI LVL Manual TEST
TASK 28-46-00-810-824-A
RIGHT HI LVL Manual TEST
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 28-46-00-710-055-A ** ON A/C NOT FOR ALL
Subtask 28-46-00-810-073-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:39:51 UTC
RIGHT HI LVL Manual TEST
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes- FLSCU-2 [9QJ]
- CTL PNL-REFUEL/DEFUEL [800VU]
- aircraft wiring
- HARNESS-CHAN A, R WING TK INR [13QT2]
- SENSOR-HI LEVEL, RIGHT WING TANK INNER CHANEL A [17QJ2]
SWITCH-TEST/HIGH/LTS (2QJ) (part of 800VU) Panel Assy-Refuel (800VU) internal wiring - HARNESS-RIGHT WING, TANK A [58QT]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 28-10-00-910-001 | Safety Procedures When You Do Work in a Fuel Tank |
| AMM 28-25-55-000-001 | Removal of the Refuel Panel |
| AMM 28-25-55-400-001 | Installation of the Refuel Panel |
| AMM 28-42-43-000-005 | Removal of the Wing Tank Harness |
| AMM 28-42-43-000-006 | Removal of the Wing-Tank Inner-Cell Group A Harness |
| AMM 28-42-43-400-005 | Installation of the Wing Tank Harness |
| AMM 28-42-43-400-006 | Installation of the Wing-Tank Inner-Cell Group A Harness |
| AMM 28-46-00-710-001 | Test of the Tank High-Level Sensing-System |
| AWM 284601 | |
| AWM 284602 | |
| AMM 28-46-15-000-001 | Removal of the Wing-Tank Fuel-Level Sensors |
| AMM 28-46-15-400-009 | Installation of the Wing-Tank Fuel-Level Sensors |
| AMM 28-46-34-000-001 | Removal of the Fuel-Level Sensing Control-Unit (FLSCU) |
| AMM 28-46-34-400-001 | Installation of the Fuel-Level Sensing Control-Unit (FLSCU) |
Subtask 28-46-00-710-055-A ** ON A/C NOT FOR ALL
A. Do the Operational Test of the HI LVL Lights AMM 28-46-00-710-001.
Subtask 28-46-00-710-055-B ** ON A/C NOT FOR ALL NOTE: You can get more Trouble-shooting data from the CFDS(FUEL):
- Input Parameters Page 3 (Ref. P. Block 301), used with the Fuel Level Sensors Operating (Changeover) Values (Ref. P. Block 301)
- FLSCU Trouble-shooting Data (Ref. P. Block 301).
NOTE: OPTIONAL TESTING:
Where a PSD A320-2 Fuel Level Sensing Test Set is available measurements can be taken before a decision is made to go into or close up a fuel tank. The Test Set enables the tank mounted components and tank wiring to be tested from the tank wall connectors.
Where a PSD A320-2 Fuel Level Sensing Test Set is available measurements can be taken before a decision is made to go into or close up a fuel tank. The Test Set enables the tank mounted components and tank wiring to be tested from the tank wall connectors.
A. Do the Operational Test of the HI LVL Lights AMM 28-46-00-710-001.
4. Fault IsolationNOTE: You can get more Trouble-shooting data from the CFDS(FUEL):
- Input Parameters Page 3 (Ref. P. Block 301), used with the Fuel Level Sensors Operating (Changeover) Values (Ref. P. Block 301)
- Trouble-shooting Data (Ref. P. Block 301).
NOTE: OPTIONAL TESTING:
Where a PSDA321-1 Test Set is available, a check can be made before a decision is made to go into or close up a fuel tank. The Test Set enables a GO/NOGO check to be made of the tank mounted components and wiring from the tank wall connectors.
Where a PSDA321-1 Test Set is available, a check can be made before a decision is made to go into or close up a fuel tank. The Test Set enables a GO/NOGO check to be made of the tank mounted components and wiring from the tank wall connectors.
Subtask 28-46-00-810-073-A ** ON A/C NOT FOR ALL
A. If the RIGHT HI LVL Indicator light fails to change state, from off to on, or from on to off:
(2) If the RIGHT HI LVL Indicator light changes state during the test but the fault has transfered to LEFT HI LVL Indicator light:
(4) If the fault continues:
(5) Remove Panel Assy-Refuel (800VU) AMM 28-25-55-000-001.
(6) Do a check AWM 284602 with a MULTIMETER - STANDARD of the SW-TEST/HI/LTS (2QJ) between:
(10) Do the test given in Para. 3.A.
(11) If the fault continues:
(a) Drain, open and vent the tank AMM 28-10-00-910-001.
(b) Do a check of the HARNESS-CHAN A, R WING TK INR [13QT2] , AWM 284602.
(c) If the harness is unserviceable:
(a) Check/replace theSWITCH-TEST/HIGH/LTS (2QJ) (part of 800VU) .
(b) Check/repair thePanel Assy-Refuel (800VU) internal wiring as follows:
(d) Do the test given in Para. 3.A.
Subtask 28-46-00-810-073-B ** ON A/C NOT FOR ALL - swap the FLSCU-2 [9QJ] with FLSCU-1 (7QJ), AMM 28-46-34-000-001, and AMM 28-46-34-400-001.
(2) If the RIGHT HI LVL Indicator light changes state during the test but the fault has transfered to LEFT HI LVL Indicator light:
- replace the FLSCU-1 (7QJ), AMM 28-46-34-000-001, and AMM 28-46-34-400-001.
(4) If the fault continues:
(5) Remove Panel Assy-Refuel (800VU) AMM 28-25-55-000-001.
(6) Do a check AWM 284602 with a MULTIMETER - STANDARD of the SW-TEST/HI/LTS (2QJ) between:
- connector 4023VC, pin <C, and connector 4024VC, pin R, on the Panel Assy-Refuel (800VU).
- open circuit for the switch in the central (released) position
- closed circuit for the switch in the TEST position.
NOTE: The LTS test checks the 28VDC supply to the Panel Assy-Refuel (800VU).
(7) Replace the CTL PNL-REFUEL/DEFUEL [800VU] , if it fails Step (6), AMM 28-25-55-000-001, and AMM 28-25-55-400-001. NOTE: If due to airline operational conditions it is not possible to replace the Panel Assy-Refuel (800VU) and internal Trouble-shooting is required, go to Step (12).
(8) If the fault continues do a wiring check AWM 284601, and AWM 284602 of the aircraft wiring : - between the Panel Assy-Refuel (800VU), connector 4024VC, pin R and the FLSCU-2 rack connector AA, pin 13B
- between the Panel Assy-Refuel (800VU), connector 4024VC, pin S and the FLSCU-2 rack connector AA, pin 7A
- between the FLSCU-2 rack connector AA, pin 6A and the DC1 ground/earth point
- between the FLSCU-2 rack connector AB, pin 10A and the tank wall connector 4039VC, pin <V
- between the FLSCU-2 rack connector AB, pin 10B and the tank wall connector 4039VC, pin EE.
(10) Do the test given in Para. 3.A.
(11) If the fault continues:
(a) Drain, open and vent the tank AMM 28-10-00-910-001.
(b) Do a check of the HARNESS-CHAN A, R WING TK INR [13QT2] , AWM 284602.
(c) If the harness is unserviceable:
- replace the harness AMM 28-42-43-000-006 and AMM 28-42-43-400-006.
- replace the SENSOR-HI LEVEL, RIGHT WING TANK INNER CHANEL A [17QJ2] AMM 28-46-15-000-001 and AMM 28-46-15-400-009.
(a) Check/replace the
(b) Check/repair the
- connector 4023VC, pin <C to terminal block 4001VT, terminal 5C
- terminal block 4001VT, terminal 5J to SW-TEST/HI/LTS (2QJ), terminal 1B
- SW-TEST/HI/LTS (2QJ), terminal 3B to connector 4024VC, pin R
- connector 4024VC, pin S to IND-HI LVL/RIGHT (4QJ), terminal I.
(d) Do the test given in Para. 3.A.
A. If the RIGHT HI LVL Indicator light fails to change state, from off to on, or from on to off:
(2) If the RIGHT HI LVL Indicator light changes state during the test but the fault has transfered to LEFT HI LVL Indicator light:
(4) If the fault continues:
(5) Remove Panel Assy-Refuel (800VU) AMM 28-25-55-000-001.
(6) Do a check AWM 284602 with a MULTIMETER - STANDARD of the SW-TEST/HI/LTS (2QJ) between:
(10) Do the test given in Para. 3.A.
(11) If the fault continues:
(a) Drain, open and vent the tank AMM 28-10-00-910-001.
(b) Do a check of the HARNESS-RIGHT WING, TANK A [58QT] , AWM 284602.
(c) If the harness is unserviceable:
(a) Check/replace theSWITCH-TEST/HIGH/LTS (2QJ) (part of 800VU) .
(b) Check/repair thePanel Assy-Refuel (800VU) internal wiring as follows:
(d) Do the test given in Para. 3.A.
- swap the FLSCU-2 [9QJ] with FLSCU-1 (7QJ), AMM 28-46-34-000-001, and AMM 28-46-34-400-001.
(2) If the RIGHT HI LVL Indicator light changes state during the test but the fault has transfered to LEFT HI LVL Indicator light:
- replace the FLSCU-1 (7QJ), AMM 28-46-34-000-001, and AMM 28-46-34-400-001.
(4) If the fault continues:
(5) Remove Panel Assy-Refuel (800VU) AMM 28-25-55-000-001.
(6) Do a check AWM 284602 with a MULTIMETER - STANDARD of the SW-TEST/HI/LTS (2QJ) between:
- connector 4023VC, pin <C, and connector 4024VC, pin R, on the Panel Assy-Refuel (800VU).
- open circuit for the switch in the central (released) position
- closed circuit for the switch in the TEST position.
NOTE: The LTS test checks the 28VDC supply to the Panel Assy-Refuel (800VU).
(7) Replace the CTL PNL-REFUEL/DEFUEL [800VU] , if it fails Step (6), AMM 28-25-55-000-001, and AMM 28-25-55-400-001. NOTE: If due to airline operational conditions it is not possible to replace the Panel Assy-Refuel (800VU) and internal Trouble-shooting is required, go to Step (12).
(8) If the fault continues do a wiring check AWM 284601, and AWM 284602 of the aircraft wiring : - between the Panel Assy-Refuel (800VU), connector 4024VC, pin R and the FLSCU-2 rack connector AA, pin 13B
- between the Panel Assy-Refuel (800VU), connector 4024VC, pin S and the FLSCU-2 rack connector AA, pin 7A
- between the FLSCU-2 rack connector AA, pin 6A and the DC ground/earth point
- between the FLSCU-2 rack connector AB, pin 10A and the tank wall connector 4039VC, pin <V
- between the FLSCU-2 rack connector AB, pin 10B and the tank wall connector 4039VC, pin EE.
(10) Do the test given in Para. 3.A.
(11) If the fault continues:
(a) Drain, open and vent the tank AMM 28-10-00-910-001.
(b) Do a check of the HARNESS-RIGHT WING, TANK A [58QT] , AWM 284602.
(c) If the harness is unserviceable:
- replace the harness AMM 28-42-43-000-005 and AMM 28-42-43-400-005.
- replace the SENSOR-HI LEVEL, RIGHT WING TANK INNER CHANEL A [17QJ2] AMM 28-46-15-000-001 and AMM 28-46-15-400-009.
(a) Check/replace the
(b) Check/repair the
- connector 4023VC, pin <C to terminal block 4001VT, terminal 5C
- terminal block 4001VT, terminal 5J to SW-TEST/HI/LTS (2QJ), terminal 1B
- SW-TEST/HI/LTS (2QJ), terminal 3B to connector 4024VC, pin R
- connector 4024VC, pin S to IND-HI LVL/RIGHT (4QJ), terminal I.
(d) Do the test given in Para. 3.A.