FQIS - FQIC Pin Programming Parity Error
TASK 28-42-00-810-850-A
FQIS - FQIC Pin Programming Parity Error
A. Referenced Information
3. Fault Confirmation
Subtask 28-42-00-865-083-A ** ON A/C NOT FOR ALL
Subtask 28-42-00-810-099-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:07 UTC
FQIS - FQIC Pin Programming Parity Error
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causesaircraft wiring between the FQIC (3QT) rack connector and terminal block (202VT) 92VU122 - FQIC [3QT]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 284201 | |
| AMM 28-42-34-000-001 | Removal of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 28-42-34-400-001 | Installation of the Fuel Quantity-Indicating Computer (FQIC) |
Subtask 28-42-00-865-083-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 28-42-00-710-099-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
B. To keep the number of computer removals to a minimum do the Power On BITE test of the FQI system as follows:
(1) Apply electrical power to the FQI system.
OR (if the FQIS is already powered).
Reset the FQIC. (Open, then after 10 seconds, close the two CBs 1QT and 2QT).
(2) When the BITE test is complete (XX shown on the FQI for 35 seconds and the display has no dashes for 60 seconds) set the MCDU to:
(a) CFDS
(b) SYSTEM REPORT/TEST
(c) FUEL
(d) FQIS STATUS.
(3) Examine the FQIS STATUS page to see if it agrees with the initial defect.
(4) If the PIN PRG PARITY ERROR 3QT message is not shown:
4. Fault Isolation(1) Apply electrical power to the FQI system.
OR (if the FQIS is already powered).
Reset the FQIC. (Open, then after 10 seconds, close the two CBs 1QT and 2QT).
(2) When the BITE test is complete (XX shown on the FQI for 35 seconds and the display has no dashes for 60 seconds) set the MCDU to:
(a) CFDS
(b) SYSTEM REPORT/TEST
(c) FUEL
(d) FQIS STATUS.
(3) Examine the FQIS STATUS page to see if it agrees with the initial defect.
(4) If the PIN PRG PARITY ERROR 3QT message is not shown:
- maintenance steps are not necessary.
Subtask 28-42-00-810-099-A ** ON A/C NOT FOR ALL
A. If the PIN PRG PARITY ERROR 3QT message is shown in Para. 3.B.(3):
Table of the FQIC pin programming connections with the FQIs shown in kilogrammes (kg)
(4) Repair all the unserviceable wiring and connectors.
(5) Do the procedure given in Para 3.B.
(6) If the fault continues replace the FQIC [3QT] , AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
- on the MCDU set to INPUT PARAMETERS, Page 3.
- make sure that it shows a 1.
- make sure they both show a 0.
- do a check of the
aircraft wiring between the FQIC (3QT) rack connector and terminal block (202VT) 92VU122 as shown in the table below, and ASM 284201.
Table of the FQIC pin programming connections with the FQIs shown in kilogrammes (kg)
| Bit position | Signal discription | FQIC Pin allocation | Terminal Block 202VT allocation | Term. Block 202VT Signal level |
|---|---|---|---|---|
| H1 G1 K1 | A320/321 KG/LBS Program pin parity | C05E C06E C05G | 16J 13A 13V | Ground/earth Not connected Not connected |
(5) Do the procedure given in Para 3.B.
(6) If the fault continues replace the FQIC [3QT] , AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
NOTE: Make sure that the FQIC to be installed is of the same type as that removed. (Simmons Precision - Sextant Avionique).