FQIS - No ARINC Data From ADIRU1(2)
TASK 28-42-00-810-847-A
FQIS - No ARINC Data From ADIRU1(2)
A. Referenced Information
3. Fault Confirmation
Subtask 28-42-00-710-096-A
Subtask 28-42-00-810-096-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:07 UTC
FQIS - No ARINC Data From ADIRU1(2)
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes- FQIC [3QT]
- ADIRU-1 [1FP1]
- ADIRU-2 [1FP2]
aircraft wiring data link between the ADIRU1(2)(1FP1(2)) and the FQIC (3QT)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 284204 | |
| AMM 28-42-34-000-001 | Removal of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 28-42-34-400-001 | Installation of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 31-32-00-860-001 | Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page |
| AMM 34-10-00-860-002 | ADIRS Start Procedure |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 28-42-00-710-096-A
A. Do the ADIRS start procedure AMM 34-10-00-860-002.
(2) Push (in) the line key adjacent to FUEL indication.
(3) Push (in) the line key adjacent to FQIS STATUS indication.
(4) If the message NO DATA FROM ADIRU1(2) is shown, do the fault isolation.
4. Fault IsolationNOTE: If the ADIRUs are not switched on it will cause the Class 3 fault message, NO DATA FROM ADIRU1(2) to be shown.
This is because in the preferred mode of FQIC operation, it uses accelerations data (for pitch and roll) supplied by the ADIRUs.
(1) On the Multipurpose Control and Display Unit (MCDU), get access to the SYSTEM REPORT/TEST Menu page AMM 31-32-00-860-001. This is because in the preferred mode of FQIC operation, it uses accelerations data (for pitch and roll) supplied by the ADIRUs.
(2) Push (in) the line key adjacent to FUEL indication.
(3) Push (in) the line key adjacent to FQIS STATUS indication.
(4) If the message NO DATA FROM ADIRU1(2) is shown, do the fault isolation.
NOTE: OPTIONAL TESTING
Where an ARINC reader and test connectors are available, the ARINC data can be checked at:
Where an ARINC reader and test connectors are available, the ARINC data can be checked at:
- the Test Connector 198VC (188VU) on the rack 80VC
- the FQIC 3QT rack connector.
Subtask 28-42-00-810-096-A
A. Temporarily replace the FQIC 3QT with a serviceable item AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
(4) Do the test given in Para. 3.A.
(5) If the fault continues:
(7) Do the test given in Para. 3.A.
NOTE: It is important to make sure that the FQIC is serviceable before you start more steps.
(1) If the message NO DATA FROM ADIRU1(2) is not shown: - complete the installation of the FQIC [3QT] , AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
- Install the initial FQIC 3QT, AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
(4) Do the test given in Para. 3.A.
(5) If the fault continues:
- do a check on the
aircraft wiring data link between the ADIRU1(2)(1FP1(2)) and the FQIC (3QT) ASM 284204.
(7) Do the test given in Para. 3.A.