FQIS - No ARINC Data From CFDIU
TASK 28-42-00-810-846-A
FQIS - No ARINC Data From CFDIU
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 28-42-00-710-095-A
Subtask 28-42-00-810-095-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:07 UTC
FQIS - No ARINC Data From CFDIU
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 284204 | |
| AMM 28-42-34-000-001 | Removal of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 28-42-34-400-001 | Installation of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 28-42-00-710-095-A
A. On the MCDU set the sequence that follows:
4. Fault Isolation- CFDS MENU
- SYSTEM REPORT/TEST
- FUEL
- CLASS 3 FAULTS.
NOTE: OPTIONAL TESTING
Where an ARINC Reader and test connectors are available, the ARINC data can be checked at:
Where an ARINC Reader and test connectors are available, the ARINC data can be checked at:
- the FQIC 3QT rack connector.
Subtask 28-42-00-810-095-A
A. If the MCDU shows the message NO DATA FROM CFDIU:
(4) Do the test given in Para. 3.A.
(5) If the fault continues:
(7) Do the test given in Para. 3.A.
- temporarily replace the FQIC 3QT with a serviceable item AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
NOTE: Para. A. has been included as it is important to make sure that the FQIC is serviceable before you start more steps.
(1) If the message NO DATA FROM CFDIU is not shown: - complete the installation of the FQIC [3QT] , AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
- Install the initial FQIC 3QT, AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
(4) Do the test given in Para. 3.A.
(5) If the fault continues:
- do a wiring check on the
aircraft wiring data link between the CFDIU (1TW) and the FQIC (3QT) ASM 284204.
(7) Do the test given in Para. 3.A.