Fuel Temperature Shows XX, Right Wing Tank


TASK 28-42-00-810-842-A
Fuel Temperature Shows XX, Right Wing Tank


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes
  • FQIC [3QT]
  • PROBE-FQI NO 2 AND TEMP, RIB 1-2 R WNG TK GROUP B [54QT2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-42-00-810-830-A
Fuel Quantity/Temperature Probe 54QT1(2), Left(Right) Wing Tank
3. Fault Confirmation
Subtask 28-42-00-710-091-A ** ON A/C NOT FOR ALL
A. On the ECAM CONTROL PANEL, push (in) the FUEL pushbutton switch (P/BSW).
   (1) Examine the fuel temperatures on the FUEL system page.
   (2) If the right wing tank fuel temperature shows correctly:
  • maintenance steps are not necessary.
NOTE: The right wing tank fuel temperature is supplied by a dual element temperature sensor located within the fuel probe 54QT2.
4. Fault Isolation
Subtask 28-42-00-810-091-A ** ON A/C NOT FOR ALL
A. If the right wing tank fuel temperature shows XX:
   (1) Examine the Post Flight Report (PFR) for the LRUs:
  • FQIC [3QT]
  • PROBE-FQI NO 2 AND TEMP, RIB 1-2 R WNG TK GROUP B [54QT2] .
NOTE: The right wing tank fuel temperature will show XXs if both temperature sensors within the fuel probe 54QT2 fail.
   (2) If the LRUs listed in Para. (1) are shown: