Fuel Temperature Shows XX, Right Outer Cell
TASK 28-42-00-810-840-A
Fuel Temperature Shows XX, Right Outer Cell
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 28-42-00-710-089-A ** ON A/C NOT FOR ALL
Subtask 28-42-00-810-089-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:07 UTC
Fuel Temperature Shows XX, Right Outer Cell
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 28-42-00-810-816-A | Fuel Quantity/Temperature Probe 33QT1(2), Left(Right) Wing Tank |
Subtask 28-42-00-710-089-A ** ON A/C NOT FOR ALL
A. On the ECAM CONTROL PANEL, push (in) the FUEL pushbutton switch (P/BSW).
(1) Examine the fuel temperatures on the FUEL system page.
(2) If the right outer cell fuel temperature shows correctly:
4. Fault Isolation(1) Examine the fuel temperatures on the FUEL system page.
(2) If the right outer cell fuel temperature shows correctly:
- maintenance steps are not necessary.
NOTE: The right outer cell fuel temperature is not shown on the FUEL System Display when the related fuel probe/temperature sensor 33QT2 is dry. Less than 130kg (290lb) of fuel in that cell.
Subtask 28-42-00-810-089-A ** ON A/C NOT FOR ALL
A. If the right outer cell fuel temperature shows XX.
(1) Examine the Post Flight Report (PFR) for the LRUs:
(2) If the LRUs identified in Para. (1) are shown:
(1) Examine the Post Flight Report (PFR) for the LRUs:
(2) If the LRUs identified in Para. (1) are shown: