W DOC AIRBUS | TSM A320F

Fuel Temperature Shows XX, Left Inner Cell


TASK 28-42-00-810-838-A
Fuel Temperature Shows XX, Left Inner Cell


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes
  • FQIC [3QT]
  • PROBE-FUEL QTY NO 2, RIB 1-2 L WNG TK INR GROUP B [22QT1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-42-00-810-805-A
Fuel Quantity/Temperature Probe 22QT1(2), Left(Right) Wing Tank
3. Fault Confirmation
Subtask 28-42-00-710-087-A ** ON A/C NOT FOR ALL
A. On the ECAM CONTROL PANEL, push (in) the FUEL pushbutton switch (P/BSW).
   (1) Examine the fuel temperatures on the FUEL system page.
   (2) If the left inner cell fuel temperature shows correctly:
  • maintenance steps are not necessary.
4. Fault Isolation
Subtask 28-42-00-810-087-A ** ON A/C NOT FOR ALL
A. If the left inner cell fuel temperature shows XX:
   (1) Examine the Post Flight Report (PFR) for the LRUs:
  • FQIC [3QT]
  • PROBE-FUEL QTY NO 2, RIB 1-2 L WNG TK INR GROUP B [22QT1] .
   (2) If the LRUs listed in Para. (1) are shown:
[Rev.8 from Aug 2018] 2026.04.04 04:29:06 UTC