Fuel Temperature Shows XX, Left Outer Cell


TASK 28-42-00-810-837-A
Fuel Temperature Shows XX, Left Outer Cell


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes
  • FQIC [3QT]
  • PROBE-FUEL QTY NO 13, RIB 16-17 L WNG TK OUTR GROUPA [33QT1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-42-00-810-816-A
Fuel Quantity/Temperature Probe 33QT1(2), Left(Right) Wing Tank
3. Fault Confirmation
Subtask 28-42-00-710-086-A ** ON A/C NOT FOR ALL
A. On the ECAM CONTROL PANEL, push (in) the FUEL pushbutton switch (P/BSW).
   (1) Examine the fuel temperatures on the FUEL system page.
   (2) If the left outer cell fuel temperature shows correctly:
  • maintenance steps are not necessary.
NOTE: The left outer cell fuel temperature is not shown on the FUEL System Display when the related fuel probe/temperature sensor 33QT1 is dry. Less than 130kg (290lb) of fuel in that cell.
4. Fault Isolation
Subtask 28-42-00-810-086-A ** ON A/C NOT FOR ALL
A. If the left outer cell fuel temperature shows XX.
   (1) Examine the Post Flight Report (PFR) for the LRUs:
  • FQIC [3QT]
  • PROBE-FUEL QTY NO 13, RIB 16-17 L WNG TK OUTR GROUPA [33QT1] .
   (2) If the LRUs listed in Para. (1) are shown: