W DOC AIRBUS | TSM A320F

Fuel, Main Transfer System - The Two Control Valves Do Not Close


TASK 28-26-00-810-802-A
Fuel, Main Transfer System - The Two Control Valves Do Not Close


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes
  • Main Transfer System - Control Valve 1 (Left) Does Not Close
  • Main Transfer System - Control Valve 2 (Right) Does Not Close
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-26-00-810-804-A
Fuel, Main Transfer System - Control Valve 1 (Left) Does Not Close
TSM TASK 28-26-00-810-805-A
Fuel, Main Transfer System - Control Valve 2 (Right) Does Not Close
AMM 28-26-00-710-001
Operational Test of the Main Transfer System
3. Fault Confirmation
Subtask 28-26-00-710-051-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the Operational Test of the Main Transfer System AMM 28-26-00-710-001.
     (a) If the main transfer system:

  • operates as specified, no troubleshooting work steps are necessary

  • does not operate as specified (and the left and right main transfer control valves do not close), do Para. 4.A.
4. Fault Isolation
Subtask 28-26-00-810-051-A ** ON A/C NOT FOR ALL
A. Procedure
   (1) If the two transfer valves do not close, do the TSM procedures that follow:
[Rev.8 from Aug 2018] 2026.04.04 04:28:47 UTC