W DOC AIRBUS | TSM A320F

Refuel/Defuel - Memo Message REFUELG Shown When Refuel/Defuel Control Panel Door is Closed


TASK 28-25-00-810-818-A
Refuel/Defuel - Memo Message REFUELG Shown When Refuel/Defuel Control Panel Door is Closed


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes
  • MSW-REFUEL/DEFUEL CTL PNL DOOR POSITION [20QU]
  • RELAY REFLNG BUS 501PP CTL (8PR)
  • FQIC [3QT]
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 246701
AMM 28-25-71-000-001
Removal of the Micro-switch
AMM 28-25-71-400-001
Installation of the Micro-switch
AMM 28-42-34-000-001
Removal of the Fuel Quantity-Indicating Computer (FQIC)
AMM 28-42-34-400-001
Installation of the Fuel Quantity-Indicating Computer (FQIC)
3. Fault Confirmation
Subtask 28-25-00-710-069-A
A. Test
   (1) If the memo message REFLUELG is shown on the ECAM when the refuel panel door 192MB/522KB/622KB is closed, and (if installed) the cockpit refuel PWR P/BSW (23QN) is set to off:
     (a) Do the Fault Isolation.
4. Fault Isolation
Subtask 28-25-00-810-069-A
A. Procedure
   (1) Do a check of the refuel panel door MSW-REFUEL/DEFUEL CTL PNL DOOR POSITION [20QU] , AMM 28-25-71-400-001.
     (a) If after the check/adjustment the panel floodlights operate correctly:
       1 Close the door and do a check of the ECAM to make sure the REFUELG message has gone.
       2 If the REFUELG message has gone no more maintenance steps are necessary.
   (2) If after adjustment the lights do not operate correctly:
     (a) Replace the MSW-REFUEL/DEFUEL CTL PNL DOOR POSITION [20QU] , AMM 28-25-71-000-001 and AMM 28-25-71-400-001.
     (b) Do the test in Para. 4. A. (1) (a).
   (3) If the REFUELG message has not gone:
     (a) Replace the RELAY REFLNG BUS 501PP CTL (8PR).
     (b) Do a check of the ECAM to make sure the REFUELG message has gone.
   (4) If the REFUELG message has not gone:
     (a) Replace FQIC [3QT] , AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
     (b) Do a check of the ECAM to make sure the REFUELG message has gone.
   (5) If the REFUELG message has not gone:
     (a) Do a check of the aircraft wiring from the RELAY REFLNG BUS 501PP CTL (8PR) to MSW-REFUEL/DEFUEL CTL PNL DOOR POSITION (20QU) ASM 246701.
     (b) Repair the defects found.
     (c) Do a check of the ECAM to make sure the REFUELG message has gone.