Fuel-Crossfeed Valve opens or closes slowly.
TASK 28-23-00-810-805-A
Fuel-Crossfeed Valve opens or closes slowly.
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 28-23-00-700-053-A
Subtask 28-23-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:40 UTC
Fuel-Crossfeed Valve opens or closes slowly.
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causes2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 28-23-00-720-001 | Operational Test of Crossfeed Valve Using Individual Motors: ... |
| AMM 28-23-41-000-001 | Removal of the Fuel Crossfeed Valve |
| AMM 28-23-41-400-001 | Installation of the Fuel Crossfeed Valve |
| AMM 28-23-51-000-001 | Removal of the Crossfeed Valve Actuator |
| AMM 28-23-51-400-001 | Installation of the Crossfeed Valve Actuator |
Subtask 28-23-00-700-053-A
A. Do the operational test of the crossfeed valve using individual motors AMM 28-23-00-720-001. Make a record of the time it takes for the actuator to get to the open and the closed position.
4. Fault IsolationSubtask 28-23-00-810-054-A
A. If the crossfeed valve takes more than 6 seconds to go to the open or the closed position.
(1) Replace the ACTUATOR-FUEL CROSSFEED VALVE [5QE] AMM 28-23-51-000-001 and AMM 28-23-51-400-001.
(2) If the fault continues:
(1) Replace the ACTUATOR-FUEL CROSSFEED VALVE [5QE] AMM 28-23-51-000-001 and AMM 28-23-51-400-001.
(2) If the fault continues:
- replace the VALVE-FUEL CROSSFEED [10QM] AMM 28-23-41-000-001 and AMM 28-23-41-400-001.