Fuel Pumps - Center Tank Pumps 1 And 2 Do Not Run And No Fault Indication Shown


TASK 28-21-00-810-833-A
Fuel Pumps - Center Tank Pumps 1 And 2 Do Not Run And No Fault Indication Shown


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
1. Possible Causes
  • C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (31QA), R25 at 121VU and C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (32QA), R26 at 121VU tripped
  • C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (31QA) 121VU
  • C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (32QA) 121VU
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 28-21-00-720-001
Functional Test of the Center-Tank Fuel Control
AMM 33-14-00-710-001
Operational Test of the Lights
3. Fault Confirmation
Subtask 28-21-00-710-082-B ** ON A/C NOT FOR ALL
A. Not applicable, the fault is evident.
4. Fault Isolation
Subtask 28-21-00-810-082-B ** ON A/C NOT FOR ALL
A. Do the Operational Test of the Annunciator Light Test System AMM 33-14-00-710-001.
   (1) Repair/replace as necessary any faults found in Para 4.A.
   (2) Have the C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (31QA), R25 at 121VU and C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (32QA), R26 at 121VU tripped.
NOTE: The legends on the above C/Bs are incorrect:
  • 31QA should read C/B-FUEL/CTR TK/PUMPS 1 CTL AND 2 IND
  • 32QA should read C/B-FUEL/CTR TK/PUMPS 2 CTL AND 1 IND.
NOTE: If only one C/B operates, the FAULT legend of the related PUMPS P/BSW will illuminate as the indication supplies are cross connected.
   (3) Reset the C/Bs if found tripped.
   (4) If unable to reset the C/Bs in 4.A.(3), replace the C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (31QA) 121VU and/or C/B-FUEL/CTR TK/PUMPS 1 AND 2/CTL AND IND (32QA) 121VU.
   (5) Do the Functional Test of the Center-Tank Fuel Control (Manual Mode) AMM 28-21-00-720-001.