Fuel Pumps - L #amp# R Wing Tank Pumps 2 Do Not Run And No Fault Indication Shown
TASK 28-21-00-810-832-A
Fuel Pumps - L & R Wing Tank Pumps 2 Do Not Run And No Fault Indication Shown
A. Referenced Information
3. Fault Confirmation
Subtask 28-21-00-710-081-A
Subtask 28-21-00-810-081-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:38 UTC
Fuel Pumps - L & R Wing Tank Pumps 2 Do Not Run And No Fault Indication Shown
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
1. Possible CausesC/B-FUEL/2/L CTL AND R IND (9QA), R24 at 121VU and C/B-FUEL/2/R CTL AND L IND (10QA), R29 at 121VU tripped C/B-FUEL/2/L CTL AND R IND (9QA) 121VU C/B-FUEL/2/R CTL AND L IND (10QA) 121VU
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 28-21-00-710-001 | Operational Test of the Wing-Tank Fuel Control |
| AMM 33-14-00-710-001 | Operational Test of the Lights |
Subtask 28-21-00-710-081-A
A. Not applicable, the fault is evident.
4. Fault IsolationSubtask 28-21-00-810-081-A
A. Do the Operational Test of the Annunciator Light Test System AMM 33-14-00-710-001.
(1) Repair/replace as necessary any faults found in Para 4.A.
(2) Have the C/B-FUEL/2/L CTL AND R IND (9QA), R24 at 121VU and C/B-FUEL/2/R CTL AND L IND (10QA), R29 at 121VU tripped .
(4) If unable to reset the C/Bs in 4.A.(3), replace the C/B-FUEL/2/L CTL AND R IND (9QA) 121VU and/or C/B-FUEL/2/R CTL AND L IND (10QA) 121VU .
(5) Do the Operational Test of the Wing-Tanks Fuel Control AMM 28-21-00-710-001.
(1) Repair/replace as necessary any faults found in Para 4.A.
(2) Have the
NOTE: If one C/B only operates, the FAULT legend of the related PUMPS P/BSW will illuminate as the indication supplies are cross connected.
(3) Reset the C/Bs if found tripped. (4) If unable to reset the C/Bs in 4.A.(3), replace the
(5) Do the Operational Test of the Wing-Tanks Fuel Control AMM 28-21-00-710-001.