Fuel Pumps - Right Wing Tank Fuel Pump No. 2 Contactor Control Failure


TASK 28-21-00-810-812-A
Fuel Pumps - Right Wing Tank Fuel Pump No. 2 Contactor Control Failure


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
WARNING: DO NOT CLOSE AN OPEN (TRIPPED) CIRCUIT BREAKER RELATED TO A FUEL-PUMP. IF YOU CLOSE THE CIRCUIT BREAKER, THERE IS A RISK:
  • OF FIRE OR OF AN EXPLOSION
  • OF DAMAGE TO THE AIRCRAFT WIRING AND STRUCTURE.
WARNING: WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causes
  • CNTOR-R WING TK PUMP 2 SPLY [20QA]
  • P/BSW-FUEL/R TK PUMPS/2 [16QA]
  • aircraft wiring
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
MULTIMETER - STANDARD
 B. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-21-00-810-804-A
Fuel Pumps - Right Wing Tank Fuel Pump No. 2 (Outer) 26QA System Malfunction
TSM TASK 28-21-00-810-828-A
Fuel - L(R) Wing Tank Pumps 2, Power Supply - C/B-7QA(8QA) Tripped
ESPM 2053210
AMM 28-21-00-710-001
Operational Test of the Wing-Tank Fuel Control
ASM 282102
3. Fault Confirmation
Subtask 28-21-00-710-099-A
A. Safety Precaution
WARNING: DO NOT CLOSE AN OPEN (TRIPPED) CIRCUIT BREAKER RELATED TO A FUEL-PUMP. IF YOU CLOSE THE CIRCUIT BREAKER, THERE IS A RISK:
  • OF FIRE OR OF AN EXPLOSION
  • OF DAMAGE TO THE AIRCRAFT WIRING AND STRUCTURE.
   (1) If you find the C/B-8QA has tripped (during a work step in this TSM TASK or a referenced out AMM TASK), you must:
     (a) Stop the initial work steps.
     (b) Do the TSM procedure, Fuel - L(R) Wing Tank Pumps 2, Power Supply - C/B-7QA(8QA) Tripped (Ref. TSM TASK 28-21-00-810-828).
     (c) Replace (or do a repair of) all the unserviceable wiring and connections ESPM 2053210 before you continue.
     (d) Close the C/B-8QA.
     (e) Continue the initial work steps.
Subtask 28-21-00-710-061-A
B. Test
   (1) If necessary, do the job set-up of the Operational Test of the Wing-Tanks Fuel Control AMM 28-21-00-710-001.
   (2) Push (in) the R TK PUMPS 2 P/BSW (16QA).
   (3) Examine the right wing-tank fuel-pump 2 symbol, on the FUEL system page, at the ECAM lower display unit.
   (4) If the symbol shows:

  • green in-line, no more maintenance steps are necessary (normal operation)

  • amber cross-line, do Para. 4.A.

  • amber LO, do the TSM procedure Right Wing Tank Pump No. 2 (Outer) 26QA System Malfunction (Ref. TSM TASK 28-21-00-810-804).
NOTE: The amber LO is only shown when the signals that follow occur at the same time:
  • the contactor closed (on)
and
  • the right tank pump 2 low fuel pressure.
4. Fault Isolation
Subtask 28-21-00-810-061-A
A. Procedure
   (1) Do the initial checks as given in:

  • step (a), with a MULTIMETER - STANDARD

and/or

  • step (b), by substitution and replacement.
     (a) Do a check of the electrical circuits ASM 282102 as follows:
       1 At the panel (contactor box) 107VU, remove the contactor-20QA.
       2 At the contactor (relay) base 20QA-A, make sure that:

  • a ground is available at terminal Z

  • 28VDC is available at terminal X, when the P/BSW-16QA is set to on (through the closed contacts B3 to B1).
       3 Replace all the unserviceable items.
       4 Make sure that the contactor-20QA removed in step 1_ is installed.
       5 Do the test given in Para. 3.B.
     (b) Swap (interchange) the items listed that follow, one at a time, with those from the left wing-tank fuel-pump 2 system:
  • the CNTOR-R WING TK PUMP 2 SPLY [20QA]
  • the P/BSW-FUEL/R TK PUMPS/2 [16QA] .
       1 Do the test given in Para. 3.B.
       2 If the fault is removed/cleared:
         a Replace all the unserviceable items.
         b Do the test given in Para. 3.B. for the left and right wing-tank fuel-pumps 2.
   (2) If the fault continues:
     (a) Do a check ASM 282102 of the aircraft wiring between:
  • the C/B-FUEL/PUMPS/2/R CTL AND L IND (10QA), terminal 2 and the P/BSW-FUEL/R TK PUMP/2 (16QA), terminal B3
  • the P/BSW-FUEL/R TK PUMP/2 (16QA), terminal B1 and the CNTOR-R WING TANK PUMP 2 SPLY (20QA), terminal X
  • the CNTOR-R WING TK PUMP 2 SPLY (20QA), terminal Z and the aircraft ground DC2 at 1175VT.
     (b) Repair all the unserviceable wiring and connectors ESPM 2053210.
     (c) Do the test given in Para. 3.B.