Intercell Transfer Valves (Left And Right Rear) - Fail To Latch At Fuel Low Level


TASK 28-15-00-810-812-A
Intercell Transfer Valves (Left And Right Rear) - Fail To Latch At Fuel Low Level


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
WARNING: WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT: EN50020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causes
  • RELAY-L OR R REAR XFR VALVE OPEN LATCH (13QP)
  • aircraft wiring
  • suppression diode across terminals X and Z of the RELAY 13QP
  • FQIC [3QT]
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
MULTIMETER - STANDARD
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 28-15-00-710-002
Operational Check of Individual Transfer Valves to Ensure Valve Shaft Rotates Valve to Open Position
ASM 281501
AMM 28-42-34-000-001
Removal of the Fuel Quantity-Indicating Computer (FQIC)
AMM 28-42-34-400-001
Installation of the Fuel Quantity-Indicating Computer (FQIC)
3. Fault Confirmation
Subtask 28-15-00-710-061-A ** ON A/C NOT FOR ALL
A. Do the Operational Test of the Intercell Transfer Valves AMM 28-15-00-710-002, (11 & 12QP ONLY).
NOTE: The intercell transfer valves (ICTVs) are motor driven and the power for these circuits is derived from the main power. The ICTVs are immobilized on battery power.
   (1) Connect a MULTIMETER - STANDARD to the RELAY-L OR R REAR XFR VALVE OPEN LATCH (13QP) as follows:
  • the multimeter negative/low input to terminal Z
  • the multimeter positive/high input to terminal X.
   (2) Disconnect the lead from terminal 3 of RELAY-L OR R REAR XFR VALVE OPEN LATCH (13QP).
   (3) After approximately 5 seconds to allow the valves to move, check that:
     (a) The L and R XFR Valves show open on the FUEL System SD Page.
     (b) The multimeter reads 28VDC.
   (4) Reconnect the lead disconnected in (2) above.
   (5) Check that:
     (a) The L and R XFR Valves remain at open on the FUEL System SD Page.
     (b) The multimeter reads 28VDC.
   (6) Open C/Bs (1QP), A10 and (2QP), A11 at 121VU
   (7) Close C/Bs (1QP), A10 and (2QP), A11 at 121VU
   (8) On the FUEL System SD Page check that the Left and Right Transfer Valves return to the closed position.
4. Fault Isolation
Subtask 28-15-00-810-061-B ** ON A/C NOT FOR ALL
A. If:
   (1) The multimeter reads 28VDC during the period that the valves are open.
   (2) The valves close when the lead is reconnected to terminal 3 in Para 3.A.(4).
   (3) Check/replace the RELAY-L OR R REAR XFR VALVE OPEN LATCH (13QP) .
   (4) Do the test given in Para 3.A.
   (5) If the multimeter does not read 28VDC in Para 3.A.(3)(b) above do a wiring check ASM 281501 of the:
  • aircraft wiring between the terminal X, of the RELAY 13QP and the pin C, of the connector AA, at ACTUATOR 11QP
  • aircraft wiring between the terminal X, of the RELAY 13QP and the pin C, of the connector AA, at ACTUATOR 12QP
  • aircraft wiring between the terminal Z, of the RELAY 13QP and the pin 10B, connector AB, at FQIC 3QT
  • suppression diode across terminals X and Z of the RELAY 13QP .
   (6) Repair/replace all the unserviceable wiring, diodes, and connectors.
   (7) Do the test given in Para 3.A.
   (8) If the fault continues replace the FQIC [3QT] AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
   (9) Do the test given in Para 3.A.