Intercell XFR System Failure (Right Wing) - Both Valves Remain Shut At Fuel Low Level
TASK 28-15-00-810-802-A
Intercell XFR System Failure (Right Wing) - Both Valves Remain Shut At Fuel Low Level
A. Referenced Information
3. Fault Confirmation
Subtask 28-15-00-865-054-A ** ON A/C NOT FOR ALL
Subtask 28-15-00-810-051-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:28:28 UTC
Intercell XFR System Failure (Right Wing) - Both Valves Remain Shut At Fuel Low Level
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
1. Possible CausesRight Wing Forward Intercell XFR VALVE (29QM/72QM/10QP) Right Wing Rear Intercell XFR VALVE (30QM/73QM/12QP)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 28-15-00-810-805-A | Intercell XFR Valve 29QM/72QM/10QP (Right Forward) Fault - Stays Closed When The Fuel In The Inner-cell Is At Low Level |
| TSM TASK 28-15-00-810-806-A | Intercell XFR Valve 30QM/73QM/12QP (Right Rear) Fault - Stays Closed When The Fuel In The Inner-cell Is At Low Level |
| AMM 28-46-00-740-001 | Functional (BITE) Test |
Subtask 28-15-00-865-054-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 28-15-00-710-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
B. Do the FLSS BITE Test AMM 28-46-00-740-001.
4. Fault IsolationNOTE: If the aircraft is already supplied with electrical power, reset the FQIC. (Open, then after 5 seconds, close the two C/Bs 1QT and 2QT). The FLSS BITE test is carried out once a short time after power up. After a two minute delay to allow the FQIC to do the BITE test, continue.
NOTE: The intercell transfer valves (ICTVs) are not tested by the COMMAND FLSS BITE option. (This option only available with 07 FQIC Software Standard).
NOTE: The ICTVs are motor driven and the power for these circuits is derived from the main power. The ICTVs are immobilized on battery power.
(1) If failures are detected examine the FLSS STATUS page for any of the messages that follow: - L LO LEVEL SENSOR 15QJ1
- R LO LEVEL SENSOR 15QJ2
- L LO LEVEL SENSOR 16QJ1
- R LO LEVEL SENSOR 16QJ2
- FLSCU1 7QJ
- FLSCU2 9QJ.
- go to step Para 4.
- trouble shoot the LRU(s) before you start more steps.
Do the trouble shooting procedure related to the failure message.
Subtask 28-15-00-810-051-A ** ON A/C NOT FOR ALL
A. Set the MCDU to SYSTEM REPORT/TEST (FUEL), then for:
- 06 FQIC Software Standard go to the FQIS STATUS page
- 07 FQIC Software Standard go to the FLSS STATUS page.
- (Ref. TSM TASK 28-15-00-810-805) for the
Right Wing Forward Intercell XFR VALVE (29QM/72QM/10QP) message - (Ref. TSM TASK 28-15-00-810-806) for the
Right Wing Rear Intercell XFR VALVE (30QM/73QM/12QP) message.