W DOC AIRBUS | TSM A320F

Operational Test of the THS Actuator Electrical Control or of the ELAC 1 and SEC 1 #amp# 2 on Pitch Control not ok


TASK 27-96-00-810-802-A
Operational Test of the THS Actuator Electrical Control or of the ELAC 1 and SEC 1 & 2 on Pitch Control not ok


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-710-022
Operational Test of the THS Actuator Electrical Control (Activation for BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-96-00-710-052-A
A. Do the Operational Test of the THS Actuator Electrical Control AMM 27-96-00-710-022.
4. Fault Isolation
Subtask 27-96-00-810-060-A
A. Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001:
  • refer to 27 ECAM for the related maintenance message,
  • do the related trouble shooting procedure.
[Rev.8 from Aug 2018] 2026.04.04 04:28:25 UTC