W DOC AIRBUS | TSM A320F

Loss of the F/CTL Page Automatic Call up during Check List


TASK 27-95-00-810-839-A
Loss of the F/CTL Page Automatic Call up during Check List


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-95-34-000-001
Removal of the FCDC
AMM 27-95-34-400-001
Installation of the FCDC
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 27-95-00-700-054-A
A. Not applicable. The fault is evident during the check list with the engines in operation.
4. Fault Isolation
Subtask 27-95-00-810-095-A
A. If the F/CTL page does not come into view automatically during the check list (Flight Phase 02):
  • On the upper ECAM DU, do a check for a warning during this phase.
Subtask 27-95-00-810-096-A
B. If there is a warning:
  • No maintenance action is necessary. Do the trouble shooting related to the warning (Ref 27 ECAM).
Subtask 27-95-00-810-097-A ** ON A/C NOT FOR ALL
C. If there is no warning:
  • do a check for the RUD position symbol on the lower ECAM DU.
   (1) If the RUD position symbol is shown:
     (a) replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
     (b) If the fault continues:
   (2) If the RUD position symbol is not shown:
     (a) If the BITE test gives a maintenance message related to the XDCR UNIT-RUDDER POS [42WV] :
  • do the related trouble shooting procedure.
     (b) If the BITE test does not give a maintenance message related to the XDCR UNIT-RUDDER POS [42WV]
Subtask 27-95-00-810-097-B ** ON A/C NOT FOR ALL
C. If there is no warning:
  • do a check for the RUD position symbol on the lower ECAM DU.
   (1) If the RUD position symbol is shown:
     (a) replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
     (b) If the fault continues:
   (2) If the RUD position symbol is not shown:
     (a) If the BITE test gives a maintenance message related to the XDCR UNIT-RUDDER POS [42WV] :
  • do the related trouble shooting procedure.
     (b) If the BITE test does not give a maintenance message related to the XDCR UNIT-RUDDER POS [42WV]