W DOC AIRBUS | TSM A320F

Loss of the FCDC1 Fail Discrete Signal for the FCDC2


TASK 27-95-00-810-833-A
Loss of the FCDC1 Fail Discrete Signal for the FCDC2


1. Possible Causes
  • wiring of the OPP FCDC FAILED (DSI 15/5) signal
  • FCDC-1 [3CE1]
  • FCDC-2 [3CE2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279505
AMM 27-95-34-000-001
Removal of the FCDC
AMM 27-95-34-400-001
Installation of the FCDC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-95-00-740-112-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-95-00-810-082-A
A. If the BITE test gives the maintenance message OPP FCDC FAIL DISCR:
  • do a check of the wiring of the OPP FCDC FAILED (DSI 15/5) signal from the FCDC1 (3CE1) to the FCDC2 (3CE2) ASM 279505.
   (1) If the fault continues:
   (2) If the fault continues:
Subtask 27-95-00-740-113-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:24 UTC