W DOC AIRBUS | TSM A320F

Loss of the FCDC 2 BUS 3 Signal for the FCDC 1


TASK 27-95-00-810-815-A
Loss of the FCDC 2 BUS 3 Signal for the FCDC 1


1. Possible Causes
  • FCDC-1 [3CE1]
  • wiring of the DGI 3/1 signal from the FCDC 1 (3CE1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279503
AMM 27-95-34-000-001
Removal of the FCDC
AMM 27-95-34-400-001
Installation of the FCDC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-95-00-740-072-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-95-00-810-061-A
A. If the BITE test gives the maintenance message:
FCDC1 OR BUS3 FROM FCDC2
   (1) If the fault continues:
  • do a check and repair the wiring of the DGI 3/1 signal from the FCDC 1 (3CE1) to the first terminal block ASM 279503.
Subtask 27-95-00-740-073-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:24 UTC