Loss of the SEC 3 BUS Signal for the FCDC 2
TASK 27-95-00-810-813-A
Loss of the SEC 3 BUS Signal for the FCDC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-95-00-740-068-A 4. Fault Isolation
Subtask 27-95-00-810-059-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:24 UTC
Loss of the SEC 3 BUS Signal for the FCDC 2
1. Possible Causes
- FCDC-2 [3CE2]
wiring of the DGI 3/2 signal from the FCDC 2 (3CE2) to the first terminal block wiring of the DGI 3/4 signal from the FCDC 2 (3CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279255 | |
| AMM 27-95-34-000-001 | Removal of the FCDC |
| AMM 27-95-34-400-001 | Installation of the FCDC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-95-00-740-068-A 4. Fault Isolation
Subtask 27-95-00-810-059-A
A. If the BITE test gives the maintenance message:
FCDC2 OR BUS FROM SEC3 COM
or
FCDC2 OR BUS FROM SEC3 MON
Subtask 27-95-00-740-069-A FCDC2 OR BUS FROM SEC3 COM
or
FCDC2 OR BUS FROM SEC3 MON
- replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- do a check and repair the
wiring of the DGI 3/2 signal from the FCDC 2 (3CE2) to the first terminal block ASM 279255 if the maintenance message is FCDC2 OR BUS FROM SEC3 COM
or - do a check and repair the
wiring of the DGI 3/4 signal from the FCDC 2 (3CE2) to the first terminal block ASM 279255 if the maintenance message is FCDC2 OR BUS FROM SEC3 MON.
B. Do the test given in Para. 3.