W DOC AIRBUS | TSM A320F

Loss of the FCDC2 Fail Discrete Signal for the FCDC1


TASK 27-95-00-810-801-A
Loss of the FCDC2 Fail Discrete Signal for the FCDC1


1. Possible Causes
  • wiring of the OPP FCDC FAILED (DSI 17/5) signal
  • FCDC-2 [3CE2]
  • FCDC-1 [3CE1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279504
AMM 27-95-34-000-001
Removal of the FCDC
AMM 27-95-34-400-001
Installation of the FCDC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-95-00-740-110-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-95-00-810-081-A
A. If the BITE test gives the maintenance message OPP FCDC FAIL DISCR:
  • do a check of the wiring of the OPP FCDC FAILED (DSI 17/5) signal from the FCDC2 (3CE2) to the FCDC1 (3CE1) ASM 279504.
   (1) If the fault continues:
   (2) If the fault continues:
Subtask 27-95-00-740-111-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:23 UTC