Loss of the FCDC2 Fail Discrete Signal for the FCDC1
TASK 27-95-00-810-801-A
Loss of the FCDC2 Fail Discrete Signal for the FCDC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-95-00-740-110-A 4. Fault Isolation
Subtask 27-95-00-810-081-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:23 UTC
Loss of the FCDC2 Fail Discrete Signal for the FCDC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279504 | |
| AMM 27-95-34-000-001 | Removal of the FCDC |
| AMM 27-95-34-400-001 | Installation of the FCDC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-95-00-740-110-A 4. Fault Isolation
Subtask 27-95-00-810-081-A
A. If the BITE test gives the maintenance message OPP FCDC FAIL DISCR:
Subtask 27-95-00-740-111-A - do a check of the
wiring of the OPP FCDC FAILED (DSI 17/5) signal from the FCDC2 (3CE2) to the FCDC1 (3CE1) ASM 279504.
- replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
B. Do the test given in Para. 3.