Loss of the Racking Inputs Signal for the SEC2
TASK 27-94-00-810-928-A
Loss of the Racking Inputs Signal for the SEC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-187-A 4. Fault Isolation
Subtask 27-94-00-810-173-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:22 UTC
Loss of the Racking Inputs Signal for the SEC2
1. Possible Causes
- SEC-2 [1CE2]
- wiring of the SEC DISCONNECTED IN THE RACK signal
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279240 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-187-A 4. Fault Isolation
Subtask 27-94-00-810-173-A
A. If the BITE test gives the maintenance message:
SEC2 RACKING INPUTS
Subtask 27-94-00-740-188-A SEC2 RACKING INPUTS
- replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the wiring of the SEC DISCONNECTED IN THE RACK signal from the SEC2 (1CE2) COM and MON part to the ground terminal ASM 279240.
B. Do the test given in Para. 3.