Failure of the SEC 2 Engagement
TASK 27-94-00-810-925-A
Failure of the SEC 2 Engagement
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-181-A 4. Fault Isolation
Subtask 27-94-00-810-170-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:22 UTC
Failure of the SEC 2 Engagement
1. Possible Causes
- SEC-2 [1CE2]
wiring of the SEC2 ENGAGED signal (DSI 04) wiring from the pushbutton switch (5CE2) P/BSW-FLT CTL/SEC 2 (5CE2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279204 | |
| AIPC 27920802 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-181-A 4. Fault Isolation
Subtask 27-94-00-810-170-A
A. If the test confirms the fault:
(1) Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(2) If the fault continues:
(a) Do a check and repair thewiring of the SEC2 ENGAGED signal (DSI 04) from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279204.
(b) Do a check and repair thewiring from the pushbutton switch (5CE2) , pin A/C1 and pin A/C3 to the first terminal block ASM 279204.
(3) If the fault continues:
Subtask 27-94-00-740-182-A (1) Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(2) If the fault continues:
(a) Do a check and repair the
(b) Do a check and repair the
(3) If the fault continues:
- Replace the
P/BSW-FLT CTL/SEC 2 (5CE2) AIPC 27920802.
B. Do the test given in Para.3.A.