W DOC AIRBUS | TSM A320F

Failure of the SEC 2 Engagement


TASK 27-94-00-810-925-A
Failure of the SEC 2 Engagement


1. Possible Causes
  • SEC-2 [1CE2]
  • wiring of the SEC2 ENGAGED signal (DSI 04)
  • wiring from the pushbutton switch (5CE2)
  • P/BSW-FLT CTL/SEC 2 (5CE2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279204
AIPC 27920802
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-181-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-170-A
A. If the test confirms the fault:
   (1) Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
   (2) If the fault continues:
     (a) Do a check and repair the wiring of the SEC2 ENGAGED signal (DSI 04) from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279204.
     (b) Do a check and repair the wiring from the pushbutton switch (5CE2), pin A/C1 and pin A/C3 to the first terminal block ASM 279204.
   (3) If the fault continues:
Subtask 27-94-00-740-182-A
B. Do the test given in Para.3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:28:22 UTC