W DOC AIRBUS | TSM A320F

Failure of the SEC 1 Engagement


TASK 27-94-00-810-924-A
Failure of the SEC 1 Engagement


1. Possible Causes
  • SEC-1 [1CE1]
  • wiring of the SEC1 ENGAGED signal (DSI4)
  • wiring from the pushbutton switch (5CE1)
  • P/BSW-FLT CTL/SEC 1 (5CE1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279204
AIPC 27920802
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-179-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-169-A
A. If the test confirms the fault:
   (1) Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
   (2) If the fault continues:
     (a) Do a check and repair the wiring of the SEC1 ENGAGED signal (DSI4) from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
     (b) Do a check and repair the wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block ASM 279204.
   (3) If the fault continues:
Subtask 27-94-00-740-180-A
B. Do the test given in Para.3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:28:22 UTC