Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the SEC 1
TASK 27-94-00-810-920-A
Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-700-133-A
Subtask 27-94-00-810-165-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:22 UTC
Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
wiring of the R ELEV SV (ANO 2) signal from the SEC 1 (1CE1) COM part to the MON part wiring from the SEC 1 (1CE1) MON part, pins AD/2F, 2G to the first terminal block wiring of the LVDT SV SPLY (34CE4) signal from the SEC 1 (1CE1) to the first terminal block wiring of the LVDT POS (ANI 3-2) signal from the SEC 1 (1CE1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279407 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-700-133-A
A. Test
(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
4. Fault Isolation(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
NOTE: Before you start the operational test procedure, release the FLT CTL/ELAC 1, FLT CTL/ELAC 2 and FLT CTL/SEC 2 pushbutton switches (on these pushbutton switches, the OFF legends come on).
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001. Subtask 27-94-00-810-165-A
A. If the test gives the maintenance message:
SEC1-COM OR WIRING TO R B ELEV SERVO VLV 34CE4
(a) Do a check of thewiring of the R ELEV SV (ANO 2) signal from the SEC 1 (1CE1) COM part to the MON part , from pins AA/2A, 2B to pins AD/2J, 2K ASM 279407:
wiring from the SEC 1 (1CE1) MON part, pins AD/2F, 2G to the first terminal block ASM 279407:
wiring of the LVDT SV SPLY (34CE4) signal from the SEC 1 (1CE1) to the first terminal block ASM 279407:
wiring of the LVDT POS (ANI 3-2) signal from the SEC 1 (1CE1) to the first terminal block ASM 279407.
Subtask 27-94-00-700-134-A SEC1-COM OR WIRING TO R B ELEV SERVO VLV 34CE4
- Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(a) Do a check of the
- If there is continuity, go to Para. (b)
- If there is no continuity, repair the above wiring.
- If there is continuity, go to Para. (c)
- If there is no continuity, repair the above wiring.
- If there is continuity go to Para. (d)
- If there is no continuity repair the above wiring.
B. Do the tests given in Para. 3.