W DOC AIRBUS | TSM A320F

Loss of the Signal of the Left Green Elevator-Servocontrol Servovalve by the SEC 2


TASK 27-94-00-810-919-A
Loss of the Signal of the Left Green Elevator-Servocontrol Servovalve by the SEC 2


1. Possible Causes
  • SEC-2 [1CE2]
  • wiring of the SV XDCR (LVDT) V1 (34CE1) signal from the SEC2 (1CE2) to the first terminal block
  • wiring of the SV XDCR (LVDT) SPLY (34CE1) signal from the SEC2 (1CE2) to the first terminal block
  • wiring of the POS XDCR MON (RVDT) (49CE1) signal from the SEC2 (1CE2) to the first terminal block
  • wiring of the POS XDCR COM (RVDT) (34CE1) signal from the SEC2 (1CE2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279408
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-700-131-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
NOTE: Before you start the operational test procedure, release the FLT CTL/ELAC 1 and FLT CTL/ELAC 2 pushbutton switches (on these pushbutton switches the OFF legends come on).
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-164-A
A. If the test gives the maintenance message:
SEC2-MON OR WIRING TO L G ELEV SERVO VLV 34CE1
   (1) If the fault continues:
     (a) Do a check of the wiring of the SV XDCR (LVDT) V1 (34CE1) signal from the SEC2 (1CE2) to the first terminal block ASM 279408:
  • If there is continuity, go to Para. (b)
  • If there is no continuity, repair the above wiring.
     (b) Do a check of the wiring of the SV XDCR (LVDT) SPLY (34CE1) signal from the SEC2 (1CE2) to the first terminal block ASM 279408:
  • If there is continuity, go to Para. (c)
  • If there is no continuity, repair the above wiring.
     (c) Do a check of the wiring of the POS XDCR MON (RVDT) (49CE1) signal from the SEC2 (1CE2) to the first terminal block ASM 279408:
  • If there is continuity, go to Para. (d)
  • If there is no continuity, repair the above wiring.
     (d) Do a check and repair the wiring of the POS XDCR COM (RVDT) (34CE1) signal from the SEC2 (1CE2) to the first terminal block ASM 279408.
Subtask 27-94-00-700-132-A
B. Do the tests given in Para. 3.