W DOC AIRBUS | TSM A320F

SEC 1 Fault without any associated maintenance message


TASK 27-94-00-810-901-A
SEC 1 Fault without any associated maintenance message


1. Possible Causes
  • RELAY-SEC 1 ANN SPLY [41CE1]
  • wiring of the RLY SEC FAULT signal from the relay to the SEC
  • SEC-1 [1CE1]
  • wiring of the DSI 4/3 (SEC 1 FAILED) signals
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279205
AIPC 27920803
AMM 27-94-00-710-002
Operational Test of the Spoiler Elevator Computer 1 (SEC 1)
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
ASM 279504
ASM 279505
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-173-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-146-A
A. If the test confirms the fault:
  • do the operational test of the SEC1 AMM 27-94-00-710-002 to make sure that the SEC1 servoes its associated surfaces.
   (1) If the flight controls move according to the SEC1 servoing:
     (a) Remove the SEC1 AMM 27-94-34-000-001.
     (b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
       1 If the resistance is less than 280 ohms:
         a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
         b Do a check of the resistance of the relay between pin X1 and X2.
       2 If the resistance is more than 400 ohms:
         a Remove the relay (41CE1).
         b Do a check of the resistance of the relay between pin X1 and X2.
  • If the resistance is more than 400 ohms:
    . replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
    . install the SEC 1 AMM 27-94-34-400-001.
  • If the resistance is between 280 and 400 ohms:
    . do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
    . install the relay
    . install the SEC 1 AMM 27-94-34-400-001.
       3 If the resistance is between 280 and 400 ohms:
         a Remove the RELAY-SEC 1 ANN SPLY (41CE1) AIPC 27920803.
         b Do a check and repair the wiring of the DSI 4/3 (SEC 1 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RELAY-SEC 1 ANN SPLY (41CE1) ASM 279504 and ASM 279505.
         c Install the SEC 1 AMM 27-94-34-400-001.
Subtask 27-94-00-740-174-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:39:10 UTC