Loss of the Side Stick Priority Signal for One SEC
TASK 27-94-00-810-895-A
Loss of the Side Stick Priority Signal for One SEC
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-700-100-A
Subtask 27-94-00-810-135-B
[Rev.8 from Aug 2018]
2026.04.04 04:28:20 UTC
Loss of the Side Stick Priority Signal for One SEC
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-932-A | Failure of the Discrete Links |
| ASM 279217 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-003 | Operational Test of the Side Stick Priority |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-700-100-A
A. Test
(1) Do the operational test of the side stick priority AMM 27-96-00-710-003.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick priority AMM 27-96-00-710-003.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
Subtask 27-94-00-810-135-B
A. If the tests give the maintenance message CHECK PRIORITY WIRING:
Subtask 27-94-00-700-101-A - do the trouble shooting (Ref. TSM TASK 31-32-00-810-932) related to the DSI 29/30 discret input signal of the SEC 1, SEC 2 and the SEC 3 ASM 279217.
- do the tests given in Para. 3. with only the SEC1 engaged for the operational test of the side stick priority.
- replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the wiring of the STICK PRIORITY CAPT (DSI29) and STICK PRIORITY F/O (DSI30) signals from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279217.
- do the tests given in Para. 3. with only the SEC2 engaged for the operational test of the side stick priority.
- replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the wiring of the STICK PRIORITY CAPT (DSI29) and STICK PRIORITY F/O (DSI30) signals from the SEC2 (1CE2) COM part and MON part to the first terminal block ASM 279217.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the wiring of the STICK PRIORITY CAPT (DSI29) and STICK PRIORITY F/O (DSI30) signals from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279217.
B. Do the tests given in Para. 3.