W DOC AIRBUS | TSM A320F

Loss of the LGCIU2 BUS2 for the SEC1


TASK 27-94-00-810-893-A
Loss of the LGCIU2 BUS2 for the SEC1


1. Possible Causes
  • SEC-1 [1CE1]
  • wiring from the LGCIU2 (5GA2) to the SEC1 (1CE1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279253
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-154-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-130-A
A. If the BITE test gives the maintenance message:
LGCIU2 OR BUS2 TO SEC1
   (1) If the fault continues:
  • do a check and repair the wiring from the LGCIU2 (5GA2) to the SEC1 (1CE1) ASM 279253.
Subtask 27-94-00-740-155-A
B. Do the test given in Para. 3.