Loss of the LGCIU2 BUS1 for the SEC2
TASK 27-94-00-810-892-A
Loss of the LGCIU2 BUS1 for the SEC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-152-A 4. Fault Isolation
Subtask 27-94-00-810-129-B
[Rev.8 from Aug 2018]
2026.04.04 04:28:19 UTC
Loss of the LGCIU2 BUS1 for the SEC2
1. Possible Causes
- SEC-2 [1CE2]
wiring from the LGCIU2 (5GA2) to the SEC2 (1CE2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279254 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-152-A 4. Fault Isolation
Subtask 27-94-00-810-129-B
A. If the BITE test gives the maintenance message:
LGCIU2 OR BUS1 TO SEC2
Subtask 27-94-00-740-153-A LGCIU2 OR BUS1 TO SEC2
- replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring from the LGCIU2 (5GA2) to the SEC2 (1CE2) ASM 279254.
B. Do the test given in Para. 3.