W DOC AIRBUS | TSM A320F

Loss of the LGCIU1 BUS2 for the SEC3


TASK 27-94-00-810-888-A
Loss of the LGCIU1 BUS2 for the SEC3


1. Possible Causes
  • SEC-3 [1CE3]
  • wiring from the LGCIU1 (5GA1) to the SEC3 (1CE3)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279255
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-144-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-125-A
A. If the BITE test gives the maintenance message:
LGCIU1 OR BUS2 TO SEC3
   (1) If the fault continues:
  • do a check and repair the wiring from the LGCIU1 (5GA1) to the SEC3 (1CE3) ASM 279255.
Subtask 27-94-00-740-145-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:19 UTC