W DOC AIRBUS | TSM A320F

Loss of the ELAC2 MON BUS1 Signal for the SEC1


TASK 27-94-00-810-887-A
Loss of the ELAC2 MON BUS1 Signal for the SEC1


1. Possible Causes
  • SEC-1 [1CE1]
  • wiring of the DGI 11 signal from the SEC1 (1CE1) COM part and MON part to the first terminal block
  • wiring of the DSI 14 signal from the SEC1 (1CE1) COM part and MON part to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-32-00-810-934-A
Failure of the Digital Links
ESPM 2052220
ASM 279249
ASM 279252
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-142-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-124-A
A. If the test gives the maintenance message:
SEC1 OR BUS 1 FROM ELAC2 MON
   (1) If the fault continues:
   (2) If the fault continues:
  • at the ELAC2 receptacle, do a check of the insulation of the wiring of the DGO 01 signal ASM 279252 ESPM 2052220.
   (3) If the fault continues:
     (a) Do a check of the wiring of the DGI 11 signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279252.
  • if there is continuity, see Para. (b)
  • if there is no continuity, repair the above wiring.
     (b) Do a check and repair the wiring of the DSI 14 signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279249.
Subtask 27-94-00-740-143-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:19 UTC