Loss of the FCDC 1 BUS 5 Signal for the SEC 2
TASK 27-94-00-810-880-A
Loss of the FCDC 1 BUS 5 Signal for the SEC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-128-A 4. Fault Isolation
Subtask 27-94-00-810-117-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:19 UTC
Loss of the FCDC 1 BUS 5 Signal for the SEC 2
1. Possible Causes
- SEC-2 [1CE2]
wiring of the DGI 10 signal from the SEC 2 (1CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| ASM 279502 | |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-128-A 4. Fault Isolation
Subtask 27-94-00-810-117-A
A. If the BITE test gives the maintenance message:
SEC2 MON OR BUS5 FROM FCDC1
Subtask 27-94-00-740-129-A SEC2 MON OR BUS5 FROM FCDC1
- replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the DGI 10 signal from the SEC 2 (1CE2) to the first terminal block ASM 279502.
B. Do the test given in Para. 3.