Loss of the FCDC 2 BUS 3 Signal for the SEC 1
TASK 27-94-00-810-879-A
Loss of the FCDC 2 BUS 3 Signal for the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-126-A 4. Fault Isolation
Subtask 27-94-00-810-116-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:18 UTC
Loss of the FCDC 2 BUS 3 Signal for the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
wiring of the DGI 10 signal from the SEC 1 (1CE1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| ASM 279503 | |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-126-A 4. Fault Isolation
Subtask 27-94-00-810-116-A
A. If the BITE test gives the maintenance message:
SEC1 MON OR BUS3 FROM FCDC2
Subtask 27-94-00-740-127-A SEC1 MON OR BUS3 FROM FCDC2
- replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the DGI 10 signal from the SEC 1 (1CE1) to the first terminal block ASM 279503.
B. Do the test given in Para. 3.