W DOC AIRBUS | TSM A320F

Loss of the FCDC 1 BUS 4 Signal for the SEC 1


TASK 27-94-00-810-878-A
Loss of the FCDC 1 BUS 4 Signal for the SEC 1


1. Possible Causes
  • SEC-1 [1CE1]
  • FCDC-1 [3CE1]
  • wiring of the DGI 10 signal from the SEC 1 (1CE1) to the FCDC 1 (3CE1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
ASM 279502
AMM 27-95-34-000-001
Removal of the FCDC
AMM 27-95-34-400-001
Installation of the FCDC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-124-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-115-A
A. If the BITE test gives the maintenance message:
SEC1 MON OR BUS4 FROM FCDC1
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the DGI 10 signal from the SEC 1 (1CE1) to the FCDC 1 (3CE1) ASM 279502.
Subtask 27-94-00-740-125-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:18 UTC