Loss of the FCDC 1 BUS 4 Signal for the SEC 1
TASK 27-94-00-810-878-A
Loss of the FCDC 1 BUS 4 Signal for the SEC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-124-A 4. Fault Isolation
Subtask 27-94-00-810-115-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:18 UTC
Loss of the FCDC 1 BUS 4 Signal for the SEC 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| ASM 279502 | |
| AMM 27-95-34-000-001 | Removal of the FCDC |
| AMM 27-95-34-400-001 | Installation of the FCDC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-124-A 4. Fault Isolation
Subtask 27-94-00-810-115-A
A. If the BITE test gives the maintenance message:
SEC1 MON OR BUS4 FROM FCDC1
Subtask 27-94-00-740-125-A SEC1 MON OR BUS4 FROM FCDC1
- replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- do a check and repair the
wiring of the DGI 10 signal from the SEC 1 (1CE1) to the FCDC 1 (3CE1) ASM 279502.
B. Do the test given in Para. 3.