W DOC AIRBUS | TSM A320F

Loss of the BUS 1 Signal for the SEC 2


TASK 27-94-00-810-875-A
Loss of the BUS 1 Signal for the SEC 2


1. Possible Causes
  • SEC-2 [1CE2]
  • wiring of the DGO 01 signal from the SEC 2 (1CE2) COM part to the first terminal block
  • wiring of the DGO 01 signal from the SEC 2 (1CE2) MON part to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-32-00-810-934-A
Failure of the Digital Links
ASM 279254
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-118-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-112-A
A. If the BITE test gives the maintenance message:
SEC2 COM BUS1
or
SEC2 MON BUS1
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the DGO 01 signal from the SEC 2 (1CE2) COM part to the first terminal block if the maintenance message is SEC 2 COM BUS 1 ASM 279254
    or
  • do a check and repair the wiring of the DGO 01 signal from the SEC 2 (1CE2) MON part to the first terminal block if the maintenance message is SEC 2 MON BUS 1 ASM 279254.
Subtask 27-94-00-740-119-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:18 UTC