Failure of the SEC3
TASK 27-94-00-810-870-A
Failure of the SEC3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-162-A 4. Fault Isolation
Subtask 27-94-00-865-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:18 UTC
Failure of the SEC3
1. Possible Causes
- RELAY-SEC 3 ANN SPLY [41CE3]
- SEC-3 [1CE3]
- wiring of the RLY SEC FAULT signal from the relay to the SEC3
- FCDC-1 [3CE1]
- FCDC-2 [3CE2]
wiring of the DSI 20/5 (SEC 3 FAILED) signals - wiring of the 28VDC GND signal
wiring of the SEC3 ENGAGED (DSI 04) signal wiring of the PLD ACTIVATION (DSI 01) signal wiring of the REVERSE LOCK AUTHORIZATION (DSI02) signal wiring from the pins A/C1 and A/C3 of the pushbutton switch (5CE3) to the first terminal block P/BSW-FLT CTL/SEC 3 (5CE3) - wiring of the DGO 03 signal
wiring from the circuit breaker (21CE3) to the first terminal block wiring from the SEC3 (1CE3) pin AC/2 for the COM part and pin AF/2 for the MON part to the circuit breaker (21CE3) wiring of the PIN PROGRAM SEC3 (DSI 16) signal wiring from the SEC3 (1CE3) pin AC/2 for the COM part and pin AF/2 for the MON part to the circuit breaker (21CE3): - wiring of the DSI 33 signal
- wiring of the DSI 34 signal
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279204 | |
| ASM 279205 | |
| AIPC 27920802 | |
| AIPC 27920803 | |
| ASM 279240 | |
| ASM 279255 | |
| AMM 27-94-00-710-001 | Operational Test of the Spoiler Elevator Computer 3 (SEC 3) |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| ASM 279504 | |
| ASM 279505 | |
| AMM 27-95-34-000-001 | Removal of the FCDC |
| AMM 27-95-34-400-001 | Installation of the FCDC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-162-A 4. Fault Isolation
Subtask 27-94-00-865-051-A
A. Table of the circuit breakers used in this procedure:
Subtask 27-94-00-810-134-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/SEC3/SPLY | 21CE3 | Q19 |
B. Do the operational test of the SEC3 AMM 27-94-00-710-001 to make sure that it does the servoing of its related surfaces.
(1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
wiring of the SEC3 ENGAGED (DSI 04) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI02) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring from the pins A/C1 and A/C3 of the pushbutton switch (5CE3) to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 3 (5CE3) AIPC 27920802.
g If the fault continues:
a do a check for a short to ground at thewiring from the SEC3 (1CE3) pin AC/2 for the COM part and pin AF/2 for the MON part to the circuit breaker (21CE3) ASM 279204:
Subtask 27-94-00-810-134-C ** ON A/C NOT FOR ALL (1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. install the SEC3 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. install the SEC3 AMM 27-94-34-400-001.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC3 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC3 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
- if the SEC3 FAULT warning message stays in view, install the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803 and go to Para. e_.
- if the SEC3 FAULT warning message goes out of view, replace the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803.
- do a check and repair the
wiring of the DSI 20/5 (SEC 3 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 3 ANN SPLY (41CE3) ASM 279504 and ASM 279505.
- do a check of the circuit breaker (21CE3) status:
- do a check for + 28VDC at pin AC/2 for the COM part and pin AF/2 for the MON part of the SEC3 (1CE3) ASM 279204.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- If the fault continues:
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. b_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. c_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. d_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. e_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. f_.
g If the fault continues:
- do a check of the wiring of the DGO 03 signal from the SEC3 (1CE3) COM part to MON part and MON part to COM part ASM 279255.
. if there is no continuity, repair the above wiring
. if there is continuity, go to Para. 2_.
- do a check and repair the
wiring from the circuit breaker (21CE3) to the first terminal block ASM 279204.
- close it.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
a do a check for a short to ground at the
- If there is a short to ground, repair the above wiring.
- If there is no short to ground, replace the circuit breaker (21CE3).
B. Do the operational test of the SEC3 AMM 27-94-00-710-001 to make sure that it does the servoing of its related surfaces.
(1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
wiring of the SEC3 ENGAGED (DSI 04) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI02) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring from the pins A/C1 and A/C3 of the pushbutton switch (5CE3) to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 3 (5CE3) AIPC 27920802.
g If the fault continues:
wiring of the PIN PROGRAM SEC3 (DSI 16) signal from the SEC3 (1CE3) COM part and MON part to the ground terminal ASM 279240:
a do a check for a short to ground at thewiring from the SEC3 (1CE3) pin AC/2 for the COM part and pin AF/2 for the MON part to the circuit breaker (21CE3) ASM 279204:
Subtask 27-94-00-810-134-D ** ON A/C NOT FOR ALL (1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. install the SEC3 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. install the SEC3 AMM 27-94-34-400-001.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC3 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the FCDC-2 [3CE2] AMM 27-95-34-000-001.
- if the SEC3 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
- if the SEC3 FAULT warning message stays in view, install the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803 and go to Para. e_.
- if the SEC3 FAULT warning message goes out of view, replace the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803.
- do a check and repair the
wiring of the DSI 20/5 (SEC 3 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 3 ANN SPLY (41CE3) ASM 279504 and ASM 279505.
- do a check of the circuit breaker (21CE3) status:
- do a check for + 28VDC at pin AC/2 for the COM part and pin AF/2 for the MON part of the SEC3 (1CE3) ASM 279204.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- If the fault continues:
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. b_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. c_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. d_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. e_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. f_.
g If the fault continues:
- do a check of the wiring of the DGO 03 signal from the SEC3 (1CE3) COM part to MON part and MON part to COM part ASM 279255:
. if there is no continuity, repair the above wiring
. if there is continuity, go to Para. h_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- do a check and repair the
wiring from the circuit breaker (21CE3) to the first terminal block ASM 279204.
- close it.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
a do a check for a short to ground at the
- If there is a short to ground, repair the above wiring.
- If there is no short to ground, replace the circuit breaker (21CE3).
B. Do the operational test of the SEC3 AMM 27-94-00-710-001 to make sure that it does the servoing of its related surfaces.
(1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
wiring of the SEC3 ENGAGED (DSI 04) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI02) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring from the pins A/C1 and A/C3 of the pushbutton switch (5CE3) to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 3 (5CE3) AIPC 27920802.
g If the fault continues:
wiring of the PIN PROGRAM SEC3 (DSI 16) signal from the SEC3 (1CE3) COM part and MON part to the ground terminal ASM 279240.
a do a check for a short to ground at thewiring from the SEC3 (1CE3) pin AC/2 for the COM part and pin AF/2 for the MON part to the circuit breaker (21CE3): ASM 279204:
Subtask 27-94-00-810-134-F ** ON A/C NOT FOR ALL (1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. install the SEC3 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. install the SEC3 AMM 27-94-34-400-001.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC3 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC3 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
- if the SEC3 FAULT warning message stays in view, install the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803 and go to Para. e_.
- if the SEC3 FAULT warning message goes out of view, replace the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803.
- do a check and repair the
wiring of the DSI 20/5 (SEC 3 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 3 ANN SPLY (41CE3) ASM 279504 and ASM 279505.
- do a check of the circuit breaker (21CE3) status:
- do a check for + 28VDC at pin AC/2 for the COM part and pin AF/2 for the MON part of the SEC3 (1CE3) ASM 279204.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- If the fault continues:
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. b_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. c_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. d_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. e_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. f_.
g If the fault continues:
- do a check of the wiring of the DGO 03 signal from the SEC3 (1CE3) COM part to MON part and MON part to COM part ASM 279255.
. if there is no continuity, repair the above wiring
. if there is continuity, go to Para. h_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- do a check and repair the
wiring from the circuit breaker (21CE3) to the first terminal block ASM 279204.
- close it.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
a do a check for a short to ground at the
- If there is a short to ground, repair the above wiring.
- If there is no short to ground, replace the circuit breaker (21CE3).
B. Do the operational test of the SEC3 AMM 27-94-00-710-001 to make sure that it does the servoing of its related surfaces.
(1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
wiring of the SEC3 ENGAGED (DSI 04) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI02) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring from the pins A/C1 and A/C3 of the pushbutton switch (5CE3) to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 3 (5CE3) AIPC 27920802.
g If the fault continues:
wiring of the PIN PROGRAM SEC3 (DSI 16) signal from the SEC3 (1CE3) COM part and MON part to the ground terminal ASM 279240:
b If there is no short to ground, replace the circuit breaker (21CE3).
2 Do a check for an open circuit of the wiring of the DSI 33 signal from the SEC3 (1CE3) COM part and MON part:
a For the COM part:
Subtask 27-94-00-810-134-J ** ON A/C NOT FOR ALL (1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. install the SEC3 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. install the SEC3 AMM 27-94-34-400-001.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC3 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the FCDC-2 [3CE2] AMM 27-95-34-000-001.
- if the SEC3 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
- if the SEC3 FAULT warning message stays in view, install the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803 and go to Para. e_.
- if the SEC3 FAULT warning message goes out of view, replace the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803.
- do a check and repair the
wiring of the DSI 20/5 (SEC 3 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 3 ANN SPLY (41CE3) ASM 279504 and ASM 279505.
- do a check of the circuit breaker (21CE3) status:
- do a check for + 28VDC at pin AC/2 for the COM part and pin AF/2 for the MON part of the SEC3 (1CE3) ASM 279204.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- If the fault continues:
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. b_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. c_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. d_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. e_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. f_.
g If the fault continues:
- do a check and repair the wiring of the DGO 03 signal from the SEC3 (1CE3) COM part to MON part and MON part to COM part ASM 279255:
. if there is no continuity, repair the above wiring
. if there is continuity, go to Para. h_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- do a check and repair the
wiring from the circuit breaker (21CE3) to the first terminal block ASM 279204.
- close it.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check for a short to ground at the
wiring from the SEC3 (1CE3) pin AC/2 for the COM part and pin AF/2 for the MON part to the circuit breaker (21CE3): ASM 279204.
b If there is no short to ground, replace the circuit breaker (21CE3).
2 Do a check for an open circuit of the wiring of the DSI 33 signal from the SEC3 (1CE3) COM part and MON part:
a For the COM part:
- pin AA/4F ASM 279240.
- pin AD/6B ASM 279240.
B. Do the operational test of the SEC3 AMM 27-94-00-710-001 to make sure that it does the servoing of its related surfaces.
(1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
wiring of the SEC3 ENGAGED (DSI 04) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI02) signal from the SEC3 (1CE3) COM part and MON part to the first terminal block ASM 279204:
wiring from the pins A/C1 and A/C3 of the pushbutton switch (5CE3) to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 3 (5CE3) AIPC 27920802.
g If the fault continues:
wiring of the PIN PROGRAM SEC3 (DSI 16) signal from the SEC3 (1CE3) COM part and MON part to the ground terminal ASM 279240.
a do a check for a short to ground at thewiring from the SEC3 (1CE3) pin AC/2 for the COM part and pin AF/2 for the MON part to the circuit breaker (21CE3): ASM 279204:
3 Do a check for an open circuit of the wiring of the DSI 34 signal from the SEC3 (1CE3) COM part and MON part:
a For the COM part:
Subtask 27-94-00-740-163-A (1) If the flight controls move in relation to the SEC3 servoing:
(a) Remove the SEC3 AMM 27-94-34-000-001.
(b) At the SEC3 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. replace the SEC-3 [1CE3] AMM 27-94-34-400-001.
a Remove the relay (41CE3).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803
. install the SEC3 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC3 ASM 279205
. install the relay
. install the SEC3 AMM 27-94-34-400-001.
a Install the SEC3 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC3 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC3 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC3 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the RELAY-SEC 3 ANN SPLY [41CE3] AIPC 27920803.
- if the SEC3 FAULT warning message stays in view, install the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803 and go to Para. e_.
- if the SEC3 FAULT warning message goes out of view, replace the RLY-SEC 3 ANN SPLY (41CE3) AIPC 27920803.
- do a check and repair the
wiring of the DSI 20/5 (SEC 3 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 3 ANN SPLY (41CE3) ASM 279504 and ASM 279505.
- do a check of the circuit breaker (21CE3) status:
- do a check for + 28VDC at pin AC/2 for the COM part and pin AF/2 for the MON part of the SEC3 (1CE3) ASM 279204.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- If the fault continues:
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. b_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. c_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. d_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. e_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. f_.
g If the fault continues:
- do a check of the wiring of the DGO 03 signal from the SEC3 (1CE3) COM part to MON part and MON part to COM part ASM 279255.
. if there is no continuity, repair the above wiring
. if there is continuity, go to Para. h_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- do a check and repair the
wiring from the circuit breaker (21CE3) to the first terminal block ASM 279204.
- close it.
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
a do a check for a short to ground at the
- If there is a short to ground, repair the above wiring.
- If there is no short to ground, replace the circuit breaker (21CE3).
3 Do a check for an open circuit of the wiring of the DSI 34 signal from the SEC3 (1CE3) COM part and MON part:
a For the COM part:
- pin AA/9H ASM 279240.
- pin AD/6D ASM 279240.
C. Do the test given in Para. 3.