Loss of the BUS 3 Signal for the SEC 2
TASK 27-94-00-810-869-A
Loss of the BUS 3 Signal for the SEC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-114-A 4. Fault Isolation
Subtask 27-94-00-810-110-A
[Rev.8 from Aug 2018]
2026.04.04 04:28:17 UTC
Loss of the BUS 3 Signal for the SEC 2
1. Possible Causes
- SEC-2 [1CE2]
wiring of the DGO3 signal from the SEC 2 (1CE2) MON part to the COM part wiring of the DGO3 signal from the SEC 2 (1CE2) COM part to the MON part
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279254 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-114-A 4. Fault Isolation
Subtask 27-94-00-810-110-A
A. If the BITE test gives the maintenance message:
SEC2 MON BUS3
or
SEC2 COM BUS3
Subtask 27-94-00-740-115-A SEC2 MON BUS3
or
SEC2 COM BUS3
- replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the DGO3 signal from the SEC 2 (1CE2) MON part to the COM part if the maintenance message is SEC 2 MON BUS 3 ASM 279254
or - do a check and repair the
wiring of the DGO3 signal from the SEC 2 (1CE2) COM part to the MON part if the maintenance message is SEC 2 COM BUS 3 ASM 279254.
B. Do the test given in Para. 3.