W DOC AIRBUS | TSM A320F

Loss of the BUS 3 Signal for the SEC 2


TASK 27-94-00-810-869-A
Loss of the BUS 3 Signal for the SEC 2


1. Possible Causes
  • SEC-2 [1CE2]
  • wiring of the DGO3 signal from the SEC 2 (1CE2) MON part to the COM part
  • wiring of the DGO3 signal from the SEC 2 (1CE2) COM part to the MON part
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 279254
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-740-114-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-110-A
A. If the BITE test gives the maintenance message:
SEC2 MON BUS3
or
SEC2 COM BUS3
   (1) If the fault continues:
  • do a check and repair the wiring of the DGO3 signal from the SEC 2 (1CE2) MON part to the COM part if the maintenance message is SEC 2 MON BUS 3 ASM 279254
    or
  • do a check and repair the wiring of the DGO3 signal from the SEC 2 (1CE2) COM part to the MON part if the maintenance message is SEC 2 COM BUS 3 ASM 279254.
Subtask 27-94-00-740-115-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:28:17 UTC