Failure of the SEC1
TASK 27-94-00-810-860-A
Failure of the SEC1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-158-A 4. Fault Isolation
Subtask 27-94-00-810-132-C ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:28:16 UTC
Failure of the SEC1
1. Possible Causes
- RELAY-SEC 1 ANN SPLY [41CE1]
- wiring of the RLY SEC FAULT signal from the relay to the SEC
- SEC-1 [1CE1]
- FCDC-1 [3CE1]
- FCDC-2 [3CE2]
wiring of the DSI 4/3 (SEC 1 FAILED) signals wiring of the + 28VDC signal - wiring of the 28VDC GND signal
wiring of the SEC1 ENGAGED (DSI 04) signal wiring of the PLD ACTIVATION (DSI 01) signal wiring of the REVERSE LOCK AUTHORIZATION (DSI 02) signal wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block P/BSW-FLT CTL/SEC 1 (5CE1) wiring of the SEC DISCONNECTED IN THE RACK (DSI 12 and DSI 28) signals wiring of the PIN PROGRAM SEC1 (DSI 07) signal - wiring of the DGO 03 signal
wiring of the PIN PROGRAM SEC1 (DSI 32) signal wiring of the PIN PROGRAM SEC1 (DSI 16) signal - wiring of the DSI 33 signal
- wiring of the DSI 34 signal
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279204 | |
| ASM 279205 | |
| AIPC 27920802 | |
| AIPC 27920803 | |
| ASM 279240 | |
| ASM 279253 | |
| AMM 27-94-00-710-002 | Operational Test of the Spoiler Elevator Computer 1 (SEC 1) |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| ASM 279504 | |
| ASM 279505 | |
| AMM 27-95-34-000-001 | Removal of the FCDC |
| AMM 27-95-34-400-001 | Installation of the FCDC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-158-A 4. Fault Isolation
Subtask 27-94-00-810-132-C ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
(a) Do a check of thewiring of the + 28VDC signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the SEC1 ENGAGED (DSI 04) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI 02) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 1 (5CE1) AIPC 27920802.
(h) If the fault continues:
1 Do a check of thewiring of the SEC DISCONNECTED IN THE RACK (DSI 12 and DSI 28) signals from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 07) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
Subtask 27-94-00-810-132-F ** ON A/C NOT FOR ALL - do the operational test of the SEC1 AMM 27-94-00-710-002 to make sure that it does the servoing of its related surfaces.
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. replace the SEC-1 [1CE1] AMM 27-94-34-400-001.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. install the SEC1 AMM 27-94-34-400-001.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC1 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC1 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
- if the SEC1 FAULT warning message stays in view, install the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803 and go to Para. e_.
- if the SEC1 FAULT warning message goes out of view, replace the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803.
- Do a check and repair the
wiring of the DSI 4/3 (SEC 1 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 1 ANN SPLY (41CE1) ASM 279504 and ASM 279505
(a) Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (b).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (c).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (d).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (e).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (f).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (g).
(h) If the fault continues:
1 Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 3_.
A. If the test confirms the fault:
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
(a) Do a check of thewiring of the + 28VDC signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the SEC1 ENGAGED (DSI 04) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI 02) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 1 (5CE1) AIPC 27920802.
(h) If the fault continues:
1 Do a check of thewiring of the SEC DISCONNECTED IN THE RACK (DSI 12 and DSI 28) signals from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 07) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 32) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 16) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
Subtask 27-94-00-810-132-G ** ON A/C NOT FOR ALL - do the operational test of the SEC1 AMM 27-94-00-710-002 to make sure that it does the servoing of its related surfaces.
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. replace the SEC-1 [1CE1] AMM 27-94-34-400-001.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. install the SEC1 AMM 27-94-34-400-001.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC1 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC1 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
- if the SEC1 FAULT warning message stays in view, install the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803 and go to Para. e_.
- if the SEC1 FAULT warning message goes out of view, replace the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803.
- Do a check and repair the
wiring of the DSI 4/3 (SEC 1 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 1 ANN SPLY (41CE1) ASM 279504 and ASM 279505.
(a) Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (b).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (c).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (d).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (e).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (f).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (g).
(h) If the fault continues:
1 Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 3_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 4_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 5_.
A. If the test confirms the fault:
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
(a) Do a check of thewiring of the + 28VDC signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the SEC1 ENGAGED (DSI 04) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI 02) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 1 (5CE1) AIPC 27920802.
(h) If the fault continues:
1 Do a check of thewiring of the SEC DISCONNECTED IN THE RACK (DSI 12 and DSI 28) signals from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 07) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 32) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 16) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
Subtask 27-94-00-810-132-L ** ON A/C NOT FOR ALL - do the operational test of the SEC1 AMM 27-94-00-710-002 to make sure that it does the servoing of its related surfaces.
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. replace the SEC-1 [1CE1] AMM 27-94-34-400-001.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. install the SEC1 AMM 27-94-34-400-001.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC1 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC1 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
- if the SEC1 FAULT warning message stays in view, install the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803 and go to Para. e_.
- if the SEC1 FAULT warning message goes out of view, replace the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803.
- Do a check and repair the
wiring of the DSI 4/3 (SEC 1 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 1 ANN SPLY (41CE1) ASM 279504 and ASM 279505.
(a) Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (b).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (c).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (d).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (e).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (f).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (g).
(h) If the fault continues:
1 Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 3_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 4_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 5_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 6_.
A. If the test confirms the fault:
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
(a) Do a check of thewiring of the + 28VDC signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring of the SEC1 ENGAGED (DSI 04) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring of the REVERSE LOCK AUTHORIZATION (DSI 02) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block ASM 279204.
P/BSW-FLT CTL/SEC 1 (5CE1) AIPC 27920802.
(h) If the fault continues:
1 Do a check of thewiring of the SEC DISCONNECTED IN THE RACK (DSI 12 and DSI 28) signals from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240.
wiring of the PIN PROGRAM SEC1 (DSI 07) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240.
wiring of the PIN PROGRAM SEC1 (DSI 32) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240.
wiring of the PIN PROGRAM SEC1 (DSI 16) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240.
a For the COM part:
Subtask 27-94-00-810-132-Q ** ON A/C NOT FOR ALL - do the operational test of the SEC1 AMM 27-94-00-710-002 to make sure that it does the servoing of its related surfaces.
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. replace the SEC-1 [1CE1] AMM 27-94-34-400-001.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. install the SEC1 AMM 27-94-34-400-001.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC1 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC1 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
- if the SEC1 FAULT warning message stays in view, install the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803 and go to Para. e_.
- if the SEC1 FAULT warning message goes out of view, replace the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803.
- do a check and repair the
wiring of the DSI 4/3 (SEC 1 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 1 ANN SPLY (41CE1) ASM 279504 and ASM 279505.
(a) Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (b).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (c).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (d).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (e).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (f).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (g).
(h) If the fault continues:
1 Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 3_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 4_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 5_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 6_.
a For the COM part:
- pin AA/4F ASM 279240.
- pin AD/6B ASM 279240.
A. If the test confirms the fault:
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pins AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
(a) Do a check of thewiring of the + 28VDC signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring of the SEC1 ENGAGED (DSI 04) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring of the REVERSE LOCK AUTHORIZATION (DSI 02) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204.
wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block ASM 279204.
P/BSW-FLT CTL/SEC 1 (5CE1) AIPC 27920802.
(h) If the fault continues:
1 Do a check of thewiring of the SEC DISCONNECTED IN THE RACK (DSI 12 and DSI 28) signals from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240.
wiring of the PIN PROGRAM SEC1 (DSI 07) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240.
wiring of the PIN PROGRAM SEC1 (DSI 16) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240.
a For the COM part:
Subtask 27-94-00-810-132-R ** ON A/C NOT FOR ALL - do the operational test of the SEC1 AMM 27-94-00-710-002 to make sure that it does the servoing of its related surfaces.
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pins AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. replace the SEC-1 [1CE1] AMM 27-94-34-400-001.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. install the SEC1 AMM 27-94-34-400-001.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC1 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC1 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
- if the SEC1 FAULT warning message stays in view, install the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803 and go to Para. e_.
- if the SEC1 FAULT warning message goes out of view, replace the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803.
- do a check and repair the
wiring of the DSI 4/3 (SEC 1 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 1 ANN SPLY (41CE1) ASM 279504 and ASM 279505.
(a) Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (b).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (c).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (d).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (e).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (f).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (g).
(h) If the fault continues:
1 Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 3_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 4_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 5_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 6_.
a For the COM part:
- pin AA/9H ASM 279240.
- pin AD/6D ASM 279240.
A. If the test confirms the fault:
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
(a) Do a check of thewiring of the + 28VDC signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the SEC1 ENGAGED (DSI 04) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the PLD ACTIVATION (DSI 01) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring of the REVERSE LOCK AUTHORIZATION (DSI 02) signal from the SEC1 (1CE1) COM part and MON part to the first terminal block ASM 279204:
wiring from the pushbutton switch (5CE1), pin A/C1 and pin A/C3 to the first terminal block ASM 279204:
P/BSW-FLT CTL/SEC 1 (5CE1) AIPC 27920802.
(h) If the fault continues:
1 Do a check of thewiring of the SEC DISCONNECTED IN THE RACK (DSI 12 and DSI 28) signals from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 07) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 32) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
wiring of the PIN PROGRAM SEC1 (DSI 16) signal from the SEC1 (1CE1) COM part and MON part to the ground terminal ASM 279240:
a For the COM part:
Subtask 27-94-00-740-159-A - do the operational test of the SEC1 AMM 27-94-00-710-002 to make sure that it does the servoing of its related surfaces.
(a) Remove the SEC1 AMM 27-94-34-000-001.
(b) At the SEC1 receptacle, do a check of the resistance between pin AB/12K and pin AE/12A ASM 279205.
1 If the resistance is less than 280 ohms:
a Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803.
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is less than 280 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. replace the SEC-1 [1CE1] AMM 27-94-34-400-001.
a Remove the relay (41CE1).
b Do a check of the resistance of the relay between pins X1 and X2.
- If the resistance is more than 400 ohms:
. replace the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
. install the SEC1 AMM 27-94-34-400-001. - If the resistance is between 280 and 400 ohms:
. do a check and repair the wiring of the RLY SEC FAULT signal from the relay to the SEC ASM 279205
. install the relay
. install the SEC1 AMM 27-94-34-400-001.
a Install the SEC1 AMM 27-94-34-400-001.
b Remove the FCDC-1 [3CE1] AMM 27-95-34-000-001.
- if the SEC1 FAULT warning message stays in view, install the FCDC-1 [3CE1] AMM 27-95-34-400-001 and go to Para. c_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-1 [3CE1] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the FCDC-2 [3CE2] AMM 27-95-34-000-001
- if the SEC1 FAULT warning message stays in view, install the FCDC-2 [3CE2] AMM 27-95-34-400-001 and go to Para. d_.
- if the SEC1 FAULT warning message goes out of view, replace the FCDC-2 [3CE2] AMM 27-95-34-000-001 and AMM 27-95-34-400-001.
- Remove the RELAY-SEC 1 ANN SPLY [41CE1] AIPC 27920803
- if the SEC1 FAULT warning message stays in view, install the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803 and go to Para. e_.
- if the SEC1 FAULT warning message goes out of view, replace the RLY-SEC 1 ANN SPLY (41CE1) AIPC 27920803.
- Do a check and repair the
wiring of the DSI 4/3 (SEC 1 FAILED) signals from the FCDC1 (3CE1) and the FCDC2 (3CE2) to the RLY-SEC 1 ANN SPLY (41CE1) ASM 279504 and ASM 279505.
(a) Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (b).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (c).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (d).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (e).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (f).
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. (g).
(h) If the fault continues:
1 Do a check of the
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 2_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 3_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 4_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 5_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 6_.
- if there is no continuity, repair the above wiring
- if there is continuity, go to Para. 7_.
a For the COM part:
- pin AA/9H ASM 279240.
- pin AD/6D ASM 279240.
B. Do the test given in Para. 3.