Loss of the IR 2 Bus 2 for the SEC 3
TASK 27-94-00-810-851-A
Loss of the IR 2 Bus 2 for the SEC 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-094-A 4. Fault Isolation
Subtask 27-94-00-810-100-B
[Rev.8 from Aug 2018]
2026.04.04 04:28:15 UTC
Loss of the IR 2 Bus 2 for the SEC 3
1. Possible Causes
- SEC-3 [1CE3]
wiring of the DGI-03 signal from the SEC 3 (1CE3) COM part to the second terminal block wiring of the DGI-03 signal from the SEC 3 (1CE3) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279255 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-094-A 4. Fault Isolation
Subtask 27-94-00-810-100-B
A. If the BITE test gives the maintenance message:
SEC3 OR BUS2 FROM IR2
Subtask 27-94-00-740-095-A SEC3 OR BUS2 FROM IR2
- replace the SEC-3 [1CE3] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the DGI-03 signal from the SEC 3 (1CE3) COM part to the second terminal block (1840VT) ASM 279255. - do a check and repair the
wiring of the DGI-03 signal from the SEC 3 (1CE3) to the first terminal block , COM and MON parts ASM 279255.
B. Do the test given in Para. 3.