Loss of the IR 1 Bus 2 for the SEC 2
TASK 27-94-00-810-849-A
Loss of the IR 1 Bus 2 for the SEC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-090-A 4. Fault Isolation
Subtask 27-94-00-810-098-B
[Rev.8 from Aug 2018]
2026.04.04 04:28:15 UTC
Loss of the IR 1 Bus 2 for the SEC 2
1. Possible Causes
- SEC-2 [1CE2]
wiring of the DGI-03 signal from the SEC 2 (1CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279254 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-090-A 4. Fault Isolation
Subtask 27-94-00-810-098-B
A. If the BITE test gives the maintenance message:
SEC2 OR BUS2 FROM IR1
Subtask 27-94-00-740-091-A SEC2 OR BUS2 FROM IR1
- replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the DGI-03 signal from the SEC 2 (1CE2) to the first terminal block , COM and MON parts ASM 279254.
B. Do the test given in Para. 3.