Loss of the IR 1 Bus 3 for the SEC 1
TASK 27-94-00-810-848-A
Loss of the IR 1 Bus 3 for the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-94-00-740-088-A 4. Fault Isolation
Subtask 27-94-00-810-097-B
[Rev.8 from Aug 2018]
2026.04.04 04:28:15 UTC
Loss of the IR 1 Bus 3 for the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
wiring of the DGI-02 signal from the SEC 1 (1CE1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279253 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-94-00-740-088-A 4. Fault Isolation
Subtask 27-94-00-810-097-B
A. If the BITE test gives the maintenance message:
SEC1 OR BUS3 FROM IR1
Subtask 27-94-00-740-089-A SEC1 OR BUS3 FROM IR1
- replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- do a check and repair the
wiring of the DGI-02 signal from the SEC 1 (1CE1) to the first terminal block , COM and MON parts ASM 279253.
B. Do the test given in Para. 3.