W DOC AIRBUS | TSM A320F

Loss of the Servo Motor 3 Signal on the THS Actuator for the SEC 2


TASK 27-94-00-810-841-A
Loss of the Servo Motor 3 Signal on the THS Actuator for the SEC 2


1. Possible Causes
  • SEC-2 [1CE2]
  • pitch trim actuator
  • wiring of the command signal from the THS actuator (9CE) to the SEC 2 (1CE2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-44-57-000-001
Removal of the Pitch Trim Actuator from the THS Actuator
AMM 27-44-57-400-001
Installation of the Pitch Trim Actuator to the THS Actuator
ASM 279413
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-710-022
Operational Test of the THS Actuator Electrical Control (Activation for BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-94-00-700-098-A
A. Test
   (1) Do the operational test of the THS actuator electrical control AMM 27-96-00-710-022.
NOTE: Do the ground setting only with the SEC 2.
   (2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-94-00-810-090-A
A. If the BITE test gives the maintenance message:
SEC2 OR OUTPUT TO THS ACTR SERVO MOT3 9CE
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the command signal from the THS actuator (9CE) to the SEC 2 (1CE2), ASM 279413.
Subtask 27-94-00-700-099-A
B. Do the tests given in Para. 3.